RUN 600 XTPRO: Service & Maintenance Manual - rev. 1.3
Page 9.9
9.6. PROGRAMMING THE HITACHI J100 INVERTER
The Hitachi inverter can be programmed using the standard keyboard. The values of the main
functions, indicated with the letter F, and those of the extended functions, indicated the letters A and
C, must be correctly configured.
With the inverter powered up, the display shows the parameters for function F 1. To display the
parameters of another main function:
5. Press the FUNC key until the desired main function appears.
6. Press the 1 key once to display the value of the parameter.
7. To modify the value, press the 1 key to increase or the 2 key to decrease.
8. To save the modified value, press the FUNC key: the display reverts to showing the value of the
selected main function.
To display the parameters of the extended functions:
8. Press the FUNC key until function F 14 appears.
9. Press the 1 key to display the code of the extended function: for example the display will show 0
to indicate A 0. When the value . 0 appears it means that the type C extended functions are
available.
10. Press the FUNC key to access the extended function: the display will show A 0.
11. Press the 1 key once to view the value of the parameter: the display will show the value of the
parameter for the selected extended function.
12. To modify the value, press the 1 key to increase, or the 2 key to decrease.
13. To save the modified value, press the FUNC key: the display will revert to showing the value of
the selected extended function.
14. Press the FUNC key again to return to the main function menu.
Incorrect programming of the inverter may result in serious damage to the machine or
improper operation potentially hazardous for the user. Therefore, carry out this
operation only if certain of being able to perform the procedure correctly.
WARNING: when the programming has been completed, remember to set displayed the
value of the parameter F1 (monitoring function).
The tables below show the values of the function parameters, and indicate which of those
parameters take on a different value from the inverter default.
MAIN FUNCTIONS
FUNCTION
Value
Default
FUNCTION
Value
Default
F 1
-
F 8
11
YES
F 2
-
F 9
03
YES
F 4
F
YES
F 10
72
YES
F 5
_ _
F 11
220
YES
F 6
15
F 14
0
YES
F 7
15
Summary of Contents for RUN 600 XTPRO
Page 1: ...SERVICE MAINTENANCE MANUAL REV 1 3...
Page 2: ......
Page 4: ......
Page 24: ...RUN 600 XTPRO Service Maintenance Manual rev 1 3 Page 2 14 Page intentionally left blank...
Page 36: ...RUN 600 XTPRO Service Maintenance Manual rev 1 3 Page 3 12 Page intentionally left blank...
Page 38: ...RUN 600 XTPRO Service Maintenance Manual rev 1 3 Page 4 2 Page intentionally left blank...
Page 82: ...RUN 600 XTPRO Service Maintenance Manual rev 1 3 Page 6 42 Page intentionally left blank...
Page 126: ...RUN 600 XTPRO Service Maintenance Manual rev 1 3 Page 8 10 Page intentionally left blank...
Page 156: ...RUN 600 XTPRO Service Maintenance Manual rev 1 3 Page 11 14 Page intentionally left blank...
Page 157: ......