RUNRACE : Service & Maintenance Manual - rev. 2.0
Page 9.3
9.2. CONFIGURATION OF SW PARAMETERS
The only configurable parameters are those for the machine lubrication. To change these values,
simultaneously press the when the
01
keys when the machine is in standby mode. The following
message will appear on the LCD:
P
A S
S
W
O R D = 0 0 0 0
T H E N E N T E R O R C L E A R
Type in the password
6144
and
ENTER
to confirm. The following message will appear on the
LCD:
L U B R I C A T I O N : W E A K = 1
M E D I U M = 2 S T R O N G = 3
To change the current configuration, press the number key (from
1
to
3
) corresponding to the
desired choice. As soon as the number has been pressed, the new configuration becomes operative
and the machine reverts to the standby state
The procedure can be aborted at any time by pressing the “Clear” key.
The above procedure modifies the duration of the lubrication cycle expressed in seconds, and the
frequency of lubrication expressed in km covered by the machine, according to the table below:
LUBRICATION
Type
Duration
Sec
Frequency
Km covered
Light 30
400
Medium 30 300
Heavy 15
100
If the machine is not equipped with the automatic lubrication system, the above
configuration parameters are ignored.
Summary of Contents for Runrace
Page 1: ...SERVICE MAINTENANCE MANUAL REV 2 0 ...
Page 2: ......
Page 4: ......
Page 28: ...RUNRACE Service Maintenance Manual rev 2 0 Page 2 18 Page intentionally left blank ...
Page 144: ...RUNRACE Service Maintenance Manual rev 2 0 Page 8 12 Page intentionally left blank ...
Page 160: ...RUNRACE Service Maintenance Manual rev 2 0 Page 9 16 Page intentionally left blank ...
Page 182: ...RUNRACE Service Maintenance Manual rev 2 0 Page 11 16 Page intentionally left blank ...
Page 183: ......