6.6. THE BELT MOTOR STARTS WITH DELAY
The problem is caused by the inverter failing to receive the enable signal (Start) or the speed signal.
THE BELT MOTOR
DOES NOT START OR
STARTS WITH DELAY
Are the Start and PWM signals
correct at the output of the CPU
board?
Are the Start signal and the
analog speed reference signal
correct at the output of the
inverter interface board?
YES
NO
YES
Replace the inverter
interface board
1
2
NO
Replace the inverter
Replace the CPU board
Follow the procedure step by step to correctly diagnose the problem. Take particular care with the
checks highlighted by circled numbers, which are described in detail below:
(1)
To check the Start signal, place a tester between pins 8 (signal) and 3 (ground) of connector
CN1 on the CPU board. When the belt is halted the measured voltage should be 0 Vdc,
whereas immediately after pressing the “Start” key on the display the measured voltage should
be 4.5 Vdc.
To check the speed PWM signal, place a tester between pins 10 (signal) and 3 (ground) of
connector CN1 on the CPU board. When the belt is halted the measured voltage should be 5
Vdc, whereas immediately after pressing the “Start” key on the display the reading should
rapidly decrease until it reaches a fixed value corresponding to the selected speed. The
variation of the signal must be accompanied by a corresponding variation in the tread belt
speed: see Table 6.7-1.
(2)
To check the Start signal, place a tester between pins 2 (signal) and 1 (ground) of connector
CN1 on the inverter interface board. When the belt is halted the reading should be -24.7 Vdc,
whereas immediately after pressing the “Start” key on the display the measured value should
be -2.7 Vdc.
To check the analog speed reference signal, place a tester between pins 5 (signal) and 6
(ground) of connector CN1 on the inverter interface board. When the belt is halted the
measured value should be 0 Vdc, whereas immediately after pressing the “Start” key on the
display the reading should rapidly increase to reach a fixed value corresponding to the selected
Summary of Contents for Runrace
Page 1: ...SERVICE MAINTENANCE MANUAL REV 2 0 ...
Page 2: ......
Page 4: ......
Page 28: ...RUNRACE Service Maintenance Manual rev 2 0 Page 2 18 Page intentionally left blank ...
Page 144: ...RUNRACE Service Maintenance Manual rev 2 0 Page 8 12 Page intentionally left blank ...
Page 160: ...RUNRACE Service Maintenance Manual rev 2 0 Page 9 16 Page intentionally left blank ...
Page 182: ...RUNRACE Service Maintenance Manual rev 2 0 Page 11 16 Page intentionally left blank ...
Page 183: ......