RUNRACE : Service & Maintenance Manual - rev. 2.0
Page 6.30
(3)
Place the tester probes between the terminals 0 (signal) and L (ground) of the inverter. Check
that during machine operation the speed shown on the display and the voltage measured on
the inverter correspond to the values shown in Table 6.7-1.
(4)
Place the tester probes between pins 5 (signal) and 6 (ground) of connector CN1 on the
inverter interface board. Check that during machine operation the speed shown on the display
and the measured voltage correspond to the values shown in Table 6.7-1.
(5)
Place the tester probes between pins 10 (signal) and 3 (ground) of connector CN2 of the
inverter interface board. Check that during machine operation the speed shown on the display
and the measured voltage correspond to the values shown in Table 6.7-1.
(6)
Place the tester probes between pins 10 (signal) and 3 (ground) of connector CN1 on the CPU
board. Check that during machine operation the speed shown on the display and the measured
voltage correspond to the values shown in Table 6.7-1.