RUNRACE : Service & Maintenance Manual - rev. 2.0
Page 6.40
Follow the procedure step by step to correctly diagnose the problem. Take particular care with the
checks highlighted by circled numbers, which are described in detail below:
(1)
See the following table:
Photocell
Photocell board
SW
Siemens SFH910
GF92015-B
M3S10
Optek OPB610
GF970711
RR52V2
(2)
Place the tester probes in series with the motor cable. When the “
↑
” or “
↓
” keys are pressed
the measured steady-state current should be less than 6 A.