RUNRACE : Service & Maintenance Manual - rev. 2.0
Page 6.47
6.16. THE HEART RATE SIGNAL IS INCORRECT
The machine displays this error if the receiver is disturbed by electromagnetic noise. In some case
the machine may show “Err” on the heart rate display.
THE HEART RATE
SIGNAL IS
INCORRECT
Is the minimum distance
between machines OK?
Is the receiver positioned
correctly, and are the
connecting cables correctly
routed?
If the TGS is present, is the
TGSRN3RACE/TGSRN2RACE
cable correctly routed?
Are there sources of
electromagnetic noise near
the receiver?
Move the machines to
the minimum distance:
see paragraph 5.1.
Position the receiver and
the cable correctly: see
paragraph 11.1
Correctly route the cable:
see paragraph 11.1.
Move the machine away
from the electromagnetic
source or attenuate the
power of the noise: see
paragraph 11.1.
NO
YES
NO
YES
NO
YES
NO
YES
1
A
Continued on the following page.