RUNRACE : Service & Maintenance Manual - rev. 2.0
Page 6.48
Is the transmitter in good
working order?
Use a known good
transmitter
YES
NO
2
Is the transmitter always
within a distance of 80 cm
from the receiver?
NO
Keep the transmitter
within the minimum
reception distance
YES
Change the receiver
A
Follow the procedure step by step to correctly diagnose the problem. Take particular care with the
checks highlighted by circled numbers, which are described in detail below:
(1)
To check for electromagnetic noise near the machine, use a frequency signal monitor
constructed as shown in the schematic below:
The circuit lights the LED for every heart beat and/or disturbance that is received: in this way
it possible to determine whether there is any interference, and identify its sources.
(2)
Check the battery power level, using a tester if possible. Otherwise use a receiver or another
“reference” machine to check operation up to a distance of about 80 cm from the receiver.
ATTENTION: Consult paragraph 11.1. “Technical notes on cardio receivers” in the
Appendix.