SYNCHRO EXCITE Class & Trend: Service & maintenance manual - rev. 2.0
Page 5.3
5.2.2.
ANALOGUE
SIGNAL
ALL STANDARD
Level
Higher than -50 dBm (59 dBµV) (-1 dBmV)
Quality
S/N (Signal to Noise ratio)
Higher than +50
dB
WARNING: If the machine is not connected to a terrestrial antenna--or if it is but the antenna
signal line is interrupted by devices such as TV distribution units, modulators, etc.--the
machine will not be able to receive a usable antenna signal for radio channel tuning.
5.3.
INSTALLATION
To correctly install the machine, proceed as follows:
1.
Ensure that the specifications and requirements for installation have been met (see paragraph:
5.1. “Specifications and requirements”).
2.
Position the machine as specified above, on a level surface that is free of vibrations and has
sufficient carrying capacity for the combined weight of the machine and user.
3.
Depending on the destination country, the machine may be shipped partially disassembled,
packed inside a special carton and fixed to a pallet, or fully assembled, wrapped in clear plastic
and fixed to a wooden pallet.
Follow the assembly operations described in the instruction sheets supplied with the machines.
Only for 500, 700 and 700WTV models.
4.
Connect the mains lead to the power inlet socket on the machine.
5.
Place the on/off switch in the 0 position.
6.
Plug the mains lead into the wall outlet.
Only for 700WTV model.
7.
Connect the antenna cable to the socket.