SYNCHRO EXCITE Class & Trend: Service & maintenance manual - rev. 2.0
Pagina 6.8
6.3.
THE DISPLAY FAILS TO ILLUMINATE
This error occurs when the power supply voltage is not reaching the upper assembly.
6.3.1.
500
AND
700
M
ODELS
Does the wall outlet supply the
correct voltage?
Is the mains lead OK?
Are the LEDs on the
Display board lit on?
Plug the machine into a
working electrical outlet
Replace the mains lead
Replace the Display
board
THE DISPLAY
DOES NOT
ILLUMINATE
NO
YES
NO
YES
NO
YES
A
1
Are the fuses OK?
Replace the fuses
YES
NO
Continued on the following page