TOP 600 XTPRO: Service & Maintenance Manual - rev. 2.0
Page 6.12
Is the transmitter always
within a distance of 80 cm
from the receiver?
NO
Keep the transmitter
within the minimum
reception distance
YES
Change the receiver
A
Follow the procedure step by step to correctly diagnose the problem. Take particular care with the
checks highlighted by the circled numbers, which are described in detail below:
(1)
To check for electromagnetic noise near the machine, use a frequency signal monitor
constructed as shown in the schematic below:
The circuit lights the LED for every heart beat and/or disturbance that is received: in this way
it possible to determine whether there is any interference, and identify its sources.
(2)
Check the battery power level, using a tester if possible. Otherwise use a receiver or another
“reference” machine to check operation up to a distance of about 80 cm from the receiver.
Consult paragraph 11.1. “Technical notes on cardio receivers” in the Appendix.
Summary of Contents for Top 600 XTPRO
Page 1: ...SERVICE MAINTENANCE MANUAL REV 2 0...
Page 2: ......
Page 4: ......
Page 8: ...TOP 600 XTPRO Service Maintenance Manual rev 2 0 Page iv Page intentionally left blank...
Page 18: ...TOP 600 XTPRO Service Maintenance Manual rev 2 0 Page 2 8 Page intentionally left blank...
Page 26: ...TOP 600 XTPRO Service Maintenance Manual rev 2 0 Page 4 2 Page intentionally left blank...
Page 58: ...TOP 600 XTPRO Service Maintenance Manual rev 2 0 Page 7 18 Page intentionally left blank...
Page 70: ...TOP 600 XTPRO Service Maintenance Manual rev 2 0 Page 9 6 Page intentionally left blank...
Page 82: ......
Page 83: ...TOP 600 XTPRO Service Maintenance Manual rev 2 0 Page intentionally left blank Page 11 1...
Page 84: ......
Page 93: ......