TOP 600 XTPRO: Service & Maintenance Manual - rev. 2.0
7.7. DISASSEMBLING THE CARDIO RECEIVER
Figure 7.7-1
Carry out the procedures described in paragraph
7.6. “Disassembling the right and left side
casings”.
1. Back off the 2 fixing bolt
a
with a 3-mm hex
T-wrench while using a 7-mm wrench to
hold its nut in place.
2. Remove the housing.
Figure 7.7-2
3. Open the housing.
4. Disconnect
connector
b.
5. Remove the RECEIVER.
To reassemble the RECEIVER, carry out the
above steps in reverse order.
Before securing the screws, make sure
that the cable is correctly positioned to
avoid squeezing it with the screws.
Page 7.7