VARIO : Service & maintenance manual- rev. 4.2
Page 6.32
6.14.2.
HR/HS
R
ECEIVER
(C
HEST
B
ELT
)
700 models
CORRECT USE OF THE CHEST BELT: Wear the chest belt take care the area of
contact with the body is humid in order to guarantee it proper works.
THERE IS NO HR
SIGNAL
(Chest Belt)
Check if the +5Vdc are at the
input of the Receiver Board.
Are present?
ARM/CPU Board
defective.
Replace.
1
NO
YES
Check if the +5Vdc are at the
output of ARM/CPU Board.
Are present?
Receiver Board
defective.
Replace.
2
YES
NO
NO
YES
A
Check the SW and the
grounding of Receiver Board.
Problem persist?
3
Replace the connecting
cable between High Kit
and Low Kit.
YES
Check if using the Hand
Sensors the Heart Rate
detected.
OK
NO
Continued on following page ...