VARIO : Service & maintenance manual- rev. 4.2
Page 6.28
6.14.
THERE IS NO HEART RATE SIGNAL
6.14.1.
HR/HS
RECEIVER
(H
AND
S
ENSOR
)
700 models
HUMAN BODY “CONTINUITY”: it’s well known that for somebody it’s very
difficult, nearly impossible, to measure their HR using the hand sensors. This due to a
lot of possible causes which could fake the “quality” of the contact between the human
skin and the HS plates, as: hands only just washed or particularly dry, acidity of the
skin and/or a particular body fat mass index. For these people it’s suggested to wear
the chest belt transmitter.
HAND SENSOR CORRECT USE: Grasp both the upper and lower plate avoiding
clenching them too hardly. Avoid washing the hands using soaps that can dry the skin
too much.
The machine displays this error if the
HR/HS Receiver
does not work or is not powered by the
CPU/ARM board:
Continued on following page ...