Maintenance and Cleansing
a. Troubleshooting
Trouble
Cause
Remedy
No power supply
Check the mains power switch
and the cables.
Fixtures do not
respond.
Fuse burned
Disconnect the power and
replace the fuse with the same
specification. If the fuse is
burned again, the problem
should be cause by the circuit.
Please consult the technician.
Incorrect or
incomplete data
connection
Check the data cable. Ensure
the signal input of the first fixture
and the output of the controller
to be connected.
Whether set to Master
mode or not
Set to Slave mode via DMX
control
Wrong DMX address
Check and unify the address
setting.
The signal port of one
lamp has failures.
Pull out the signal output and
input of one fixture. Then
connect both directly. If it works
well, this fixture is proved to be
the failed one. Handle the rest
fixtures alike to check which
fixture has problems. If any
problem, please connect the
technician.
The reset is normal.
But the fixtures do
not respond or act
abnormally via
controller or Master
/Slave.
The signal output of the
controller doesn’t match
the signal input of the
lamp.
(
PINS2—3
incorrect
)
dial
“
PHASE
”,
interchange PIN2
and PIN3’s position
b. Cleansing
SRL-6078S requires simple routine maintenance to secure its long life span and
best performance.
1. Maintain the cleaning of the fan and the air vents. Dust should be removed from the fan
and the vents periodically to secure the cooling and heat dissipation.
2. Maintain the cleaning of the optical components.
3. Check the wires such as the wire connection or the earthed wire periodically to secure
the safety.
8