background image

 

32

SPECIFICATIONS: 

 

Temperature measuring range: 

Indoor 

 

 

 

:  -9.9ºC to +59.9ºC with 0.1°C resolution  

 

 

 

 

  14.2ºF to 139.8ºF with 0.2ºF resolution 

 

 

 

(“OF.L” displayed if outside this range)  

Outdoor 

 

 

 

:  -39.9ºC to +59.9ºC with 0.1°C resolution 

 

 

 

 

 

-39.8ºF to +139.8ºF with 0.2ºF resolution  

 

 

 

(“OF.L” displayed if outside this range)   

Indoor humidity range   

 

:  1% to 99% with 1% resolution 

(Display “- -“ if temperature is OL.F; display “- -“ if < 1% and “99%” if > 99%) 
Outdoor humidity range   

:   1% to 99% with 1% resolution  

(Display “- -“ if outside temperature is OF.L; display 1% if < 1% and 99% if > 99%) 
Interior data checking intervals 
Indoor Temperature 

 

:  Every 15 seconds 

Humidity  

 

:  Every 20 seconds 

Air pressure checking interval   

:   Every 15 seconds 

Outdoor temperature and humidity data checking interval: 

Every 4 seconds  

(or every 15 minutes if data are lost and display “--.-“) 

 

Transmission range 

 

:  up to 100 meters (open space) 

Power consumption: 

(alkaline batteries recommended) 

Weather station 

 

:  3 x AA, IEC LR6, 1.5V  

Thermo-hygro transmitter 

 

:  2 x AA, IEC LR6, 1.5V  

Battery life 

 

 

:  up to 24 months 

Dimensions (L x W x H): 

 

 

Weather station 

 

:  117.4 x 31.2 x 227.1mm  

Thermo-hygro transmitter 

 

:  57.3 x 62 x 135.6 mm (excluding wall bracket) 

 

LIABILITY DISCLAIMER 

• 

The electrical and electronic wastes contain hazardous substances. Disposal of 
electronic waste in wild country and/or in unauthorized grounds strongly damages the 
environment 

• 

Please contact your local or/and regional authorities to retrieve the addresses of legal 
dumping grounds with selective collection 

• 

All electronic instruments must from now on be recycled.  User shall take an active part 
in the reuse, recycling and recovery of the electrical and electronic waste. 

• 

The unrestricted disposal of electronic waste may do harm on public health and the 
quality of environment. 

• 

This product must however not be thrown in general rubbish collection points.  

• 

As stated on the gift box and labeled on the product, reading the “User manual” is 
highly recommended for the benefit of the user.  

• 

The manufacturer and supplier cannot accept any responsibility for any incorrect 
readings and any consequences that occur should an inaccurate reading take place. 

• 

This product is not to be used for medical purposes or for public information.  

• 

This product is only designed to be used in the home as indication of the future 
weather and is not 100% accurate.  Weather forecasts given by this product should be 
taken only as an indication and not as being totally accurate. 

• 

The specifications of this product may change without prior notice. 

• 

This product is not a toy. Keep out of the reach of children. 

• 

No part of this manual may be reproduced without written consent of the manufacturer.    

 

 

 

R&TTE Directive 1999/5/EC 

Summary of the Declaration of Conformity :  We hereby 
declare that this wireless transmission device does comply 
with the essential requirements of R&TTE Directive 
1999/5/EC.

 

Summary of Contents for WS 9032

Page 1: ...duct is simple and straightforward By reading this operating manual the user will receive a better understanding of the Weather Station together with the optimum benefit of all its features FEATURES T...

Page 2: ...e LED back light Low battery indicator Table standing or wall mounting Thermo Hygro Transmitter Remote transmission of outdoor temperature and humidity to weather station by 868 MHz signals Wall mount...

Page 3: ...e transmitter The outdoor temperature and humidity should then be displayed on the weather station If this does not happen after 2 minutes the batteries will need to be removed from both units and res...

Page 4: ...ms basements superstructures the received signal is naturally weakened In extreme cases please place the unit close to a window and or point its front or back towards the Frankfurt transmitter During...

Page 5: ...outdoor temperature humidity data Increase change toggle all values in manual set mode Press to set the alarm minute inside alarm setting mode Stop the alarm during alarm ringing Stop snooze mode Back...

Page 6: ...al settings can be changed when pressing the SET key for LCD contrast setting Time zone setting Time reception ON OFF setting 12 24 hour format setting Manual time setting Calendar setting C F tempera...

Page 7: ...ock will then work as a normal Quartz clock Default setting is ON 1 The digit ON will start flashing on the LCD 2 Use the OUT key to turn OFF the time reception function 3 Confirm with the SET key and...

Page 8: ...lly updated However if the signals are not received the date can also be set manually 1 The year starts flashing 2 Use the OUT key to set the year between year 2003 2029 3 Press the SET key again to c...

Page 9: ...icon sensitivity setting WEATHER FORECASTING ICON SENSITIVITY SETTING For locations with rapid changes of weather conditions the weather icons sensitivity can be set to a different level for faster di...

Page 10: ...s in Snooze mode To stop the snooze function when it is in snooze period press any key except the SNOOZE CH key To stop the alarm press any key during alarm ringing except the SNOOZE CH key MOON PHASE...

Page 11: ...sunny icon or worse with rainy icon since the icons are already at their extremes The icons displayed forecasts the weather in terms of getting better or worse and not necessarily sunny or rainy as e...

Page 12: ...ast 24 hours in 7 steps 0h 3h 6h 9h 12h 18h and 24h The 0h represents the current full hour air pressure recording The columns represent the hPa 0 2 4 6 at specific time The 0 in the middle of this sc...

Page 13: ...outdoor section of the Weather station during normal operation please check the following points 1 The distance of the Weather station or transmitters should be at least 2 meters away from any interfe...

Page 14: ...it may then either reduce or increase the transmitting range For this reason we recommend not placing the unit on any metal surfaces or in any position where a large metal or highly polished surface...

Page 15: ...the environment Please contact your local or and regional authorities to retrieve the addresses of legal dumping grounds with selective collection All electronic instruments must from now on be recycl...