background image

To delete a user (Manager only) 

 

If a user’s code is no longer required it can be deleted 

  Press and hold 3 until a double beep sounds 

  Enter the manager code  

  Enter  the  user  ID  number  from  1-9.  A  double  beep 

will sound to confirm deletion of the user. 

 
To disable all users (Manager only) 

 

All  users  can  be  temporarily  be  disabled  without 
deleting their codes 
Press and hold 2 until a double beep sounds 
Enter the manager code  
A double beep will sound to confirm that all users have 
been disabled. 
 

To enable all users (Manager only) 

 

If  all  users  have  been  disabled,  their  codes  can  be  re-
enabled 

  Press and hold 2 until a double beep sounds 

  Enter the manager code  

A double beep will sound to confirm that all  users have 
been enabled. 
 

To check user status (Manager only) 

 

The  status  of  users,  whether  activated  or  deleted  can 
be checked 

  Press and hold 7 until a double beep sounds 

  Enter the manager code, a double beep will sound 

  Press each user ID in turn 

A double beep indicates the user is active 
A single beep indicates the user is deleted 

  Press 0 to leave the menu 

 

Checking  user  status  operates  if  all  users  are  disabled 
or enabled. 

 

To audit the lock (Manager only) 

 

Full  technical  instructions  for  taking  an  audit  are 
available  with  the  audit  software.  The  command 
required on the lock is: 

  Press and hold 7 until a double beep sounds 

  Enter the manager code 

  Firmly  hold  a  DS1996  Dallas  iButton  to  the  Dallas 

reader until a double beep sounds. 

 
To add time delay values (Manager only) 

 

  Press and hold 9 until a double beep sounds 

  Enter the manager code, a double beep will sound 

  Enter 2 digits to indicate the time delay period 01-99 

minutes.  Enter  2  digits  to  indicate  the  open  window 
period 01-19 minutes. A double beep will sound  

  Re-enter the 4 digits to confirm 

 

A  double  beep  will  sound  to  confirm  that  the  values 
have been set. 

To change time delay values (Manager only) 

 

To  increase  time  delay  values  follow  the  steps  in  “To 
enter time delay values”. 

 

To decrease or remove time delay values, the operation 
must  be  performed  during  the  open  window  before  the 
user  or  manager  code  is  entered.  To  decrease,  follow 
the steps in “To enter time delay values” 
To remove: 

  Press and hold 9 until a double beep sounds 

  Enter the manager code, a double beep will sound 

  Enter 00 to indicate the time delay period should be 

0  minutes.  Enter  01  to  indicate  the  open  window 
should not be operational. A double beep will sound. 

  Re-enter 0001 to confirm.  

 

A  double  beep  will  sound  to  confirm  that  values  have 
been set. The open window will continue. 

 

Optional Feature 

– Dual Mode 

 

If  the  lock  has  been  supplied  in  dual  mode,  user  1  is 
installed with the default code 1-1-1-1-1-1. 

 

To open the lock 

Two valid codes must be entered to open the lock, one 
of which can be a manager code. 

 

To open the lock when time delay is active 

One code is required to start time delay, and two codes 
are  required  to  open  the  lock  during  the  open  window. 
User 9 may override time delay with a single code. 

 

To perform a manager function 

A valid  user code must be entered before following the 
standard manager function procedure. 

 

Optional Feature 

– Alarm signals 

 

To enter a duress code 

If  the  feature  has  been  enabled,  a  duress  code  can  be 
entered  which  will open the lock and also send a silent 
signal to the alarm system to notify others that the lock 
is being opened under duress. 
The duress code is the user’s normal code, but the last 
digit should be increased by 1, for example: 

 

 

Normal code: 1-2-3-4-5-6 

 

Duress code: 1-2-3-4-5-7 

 

If the last digit is a 9, it should be changed to 0 

 

If time delay is active, either the first code to initiate time 
delay, or the code entered during the open window can 
be duress codes. 

 

If the lock is supplied in dual mode, either or both codes 
can be duress codes.  

 

Signals if remote block is active 

If the lock system is connected to an alarm and an input 
signal is received, the lock will  sound a long beep after 
entry  of  a  valid  code  to  indicate  that  it  is  disabled  from 
opening. 