Technosoft 2021
20
iPOS360x HX-CAN Technical Reference
3.5.4 24V Digital I/O Connection
3.5.4.1
PNP inputs
Figure 3.5.4.1
24V Digital PNP Inputs connection
Remarks:
1. If Vlog is not supplied, the digital inputs will not work.
2. The inputs are selectable as PNP/ NPN by software.
3. When sets as PNP, the inputs are compatible with PNP type outputs (input must receive a positive voltage
value (5-36V) to change its default state)
3.5.4.2
NPN inputs
Figure 3.5.4.2.
24V Digital NPN Inputs connection
Remarks:
1. If Vlog is not supplied, the digital inputs will not work.
2. The inputs are selectable as PNP/ NPN by software.
3. When sets as NPN, the inputs are compatible with NPN type outputs (input must be pulled to GND to change
its default state)