Technosoft 2014
33
iPOS4808 MX Technical Reference
2.5.17. CAN-Bus
Min.
Typ.
Max.
Units
Standards compliance
ISO11898, CiA-301v4.2 & 402v3.0
Bit rate
Depending on software settings
125
1000
Kbps
Bus length
1Mbps
25
m
500Kbps
100
≤
250Kbps
250
Termination resistor
Between CAN-Hi, CAN-Lo
none on-board
Node addressing
Strapping option (AxisID0,1,2)
1 ÷ 127 (CANopen); 1-195
& 255 (TMLCAN)
-
ESD protection
Human body model
±15
KV
2.5.18. Supply Output (+5V)
Min.
Typ.
Max.
Units
+5V output voltage
Current sourced = 250mA
4.8
5
5.2
V
+5V output current
600
650
mA
Short-circuit protection
NOT protected
Over-voltage protection
NOT protected
ESD protection
Human body model
±1
KV
†
Stresses beyond values listed under “absolute maximum ratings” may cause permanent damage to the device.
Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
0,0
1,0
2,0
3,0
4,0
5,0
6,0
7,0
8,0
9,0
C
u
rr
e
n
t
[A
]
Temperature [°C]
De-rating Temperature
De-rating Current
Figure 2.15
iPOS4808 MX De-rating with ambient temperature
Summary of Contents for iPOS4808 MX Series
Page 2: ......
Page 4: ......
Page 14: ... Technosoft 2014 XII iPOS4808 MX Technical Reference This page is empty ...
Page 37: ... Technosoft 2014 35 iPOS4808 MX Technical Reference ...
Page 69: ... Technosoft 2014 67 iPOS4808 MX Technical Reference Figure 3 23 Multiple Axis CAN network ...
Page 112: ... Technosoft 2014 110 iPOS4808 MX Technical Reference This page is empty ...
Page 113: ......
Page 114: ......