IO-iPOS4808MY Technical Reference
3.10 First Power Up
In order to setup the drive for your application you need to communicate with it. The easiest way is via an
USB link between your PC and the drive.
Before the first power up, check the following:
2.
iPOS4808
mounting: it shall be fully inserted in the
IO-iPOS4808
board. J1 of drive to J1 of IO, J2 to
J2, etc.
3. Motor connections
4. USB cable connections
5.
IO-iPOS4808MY
board jumpers settings.
6. The default SS1 settings select the TMLCAN protocol with the axisID is 255 (all switches are 0). In
order to quickly change to CANopen protocol, set switch 8 and 1 from SS1 = 1. The CANopen axisID
set will be 1 (because of switch 1=1).
7. Power on the
IO-iPOS4808MY
board, the
OUT2/ Ready
LED and the +Vlog LED should light up as
green.