General information and technical specifications of CAN UP 27 / Technical specifications / CAN/S6 digital interface protocol and characteristics
CAN UP 27 online telematics gateway. Operation manual. Version 1.0
© Technoton, 2017
17
1.4.3 CAN/S6 digital interface protocol and characteristics
Characteristics of the CAN/S6 digital interface of
CAN UP 27
comply with
S6 Technology
. Data
transfer protocol is based on SAE J1939 standard and meets its requirements.
Basic mode of data reception/transmission is automatic. Baud rate value is 250 Kbit/s.
For CAN UP 27 configuration via K-Line interface (ISO 14230) Service CAN UP service software
is used (software is downloaded from the website
http://www.jv-technoton.com/soft
).
CAN UP 27 can work with any
PGN
from
S6 Database
. For Report generation, you can choose
any type of
SPN
except text.
To identify CAN UP 27 and other Units using S6 Technology, you must specify the unique
network addresses (SA) using the service software according to table 2.
Table 2 — Allowed network address of Units
Units S6
Maximum quantity at
single Vehicle*
Recommended
network
addresses (SA)
CAN UP 27 Online telematics gateway
1 pc.
100
DFM CAN
Fuel flow meter
1 pc.
111
DUT-E CAN
Fuel level sensors
2 pcs.
101, 102
MasterCAN CC
Vehicle data interfaces
2 pcs.
142
MasterCAN V-Gate
Vehicle data interfaces
2 pcs.
125, 145
MasterCAN Diagnostic
Diagnostic gate
2 pcs.
123, 143
FMSCrocodile CCAN
Contactless reader-converter
1 pc.
122
MasterCAN DAC15
Digital to analog converter
1 pc.
126
*
Quantity of
Units
is specified for CAN UP 27 Standard. CAN UP 27 Pro is able to operate
with maximum possible (for S6 architecture) quantity of Units. Allowed Unit addresses
are specified in
S6 Operation Manual
.