background image

CAN UP 27 installation / Operational restrictions 

 

 

CAN UP 27 online telematics gateway. Operation manual. Version 1.0

 

© Technoton, 2017 

21

 

2.2 Operational restrictions 

 
 

ATTENTION:

 

When  mounting 

CAN  UP  27

  on  Vehicle,  take  in  account  that 

GLONASS/GPS and GSM antennas are located inside body of CAN UP. 
Therefore, to  ensure unobstructed reception of signals from GNSS, it is necessary to 
provide a 

maximum view of the sky

 at place of CAN UP 27 mounting. 

 

CAN UP 27 installation should be done in  a dry location protected from aggressive impact of 
the  environment.  CAN  UP  27  should  not  be  mounted  near  heating  and  cooling  devices  
(e.g. the climate  control system). Also, it is not recommended to mount CAN UP 27 close to 
the vehicle electrical circuits. 

A  suitable  location  to  mount  CAN  UP  27  is  inside  driver’s  cabin.  LED-indicators  of  installed  
CAN UP 27 should not be in driver's sight to avoid distraction from driving. 

 
 

 

Summary of Contents for CAN UP 27

Page 1: ...ONLINE TELEMATICS GATEWAY CAN UP 27 OPERATION MANUAL Version 1 0...

Page 2: ...27 installation 20 2 1 Exterior inspection prior to starting works 20 2 2 Operational restrictions 21 2 3 SIM card installation 22 2 4 Configuration of CAN UP 27 23 2 4 1 Connecting CAN UP 27 to PC 23...

Page 3: ...Revision history CAN UP 27 online telematics gateway Operation manual Version 1 0 Technoton 2017 3 Revision history Version Date Editor Description of changes 1 0 08 2017 OD Basic version...

Page 4: ...e telematics gateway Operation manual Version 1 0 Technoton 2017 4 Structure of external links Document Center S6 Website JV Technoton Website MasterCAN Website ORF 4 Website Wialon Website CAN UP 27...

Page 5: ...a combined group of S6 parameters which has common name and number Functional modules FM of the Unit can have input output PGNs and setup PGNs SPN Suspect Parameter Number informational unit of S6 Eac...

Page 6: ...Counter cumulative numerical characteristic of Parameter Counter is displayed by a single number and over time its value is increasing Examples of counters fuel consumption trip engine hours counter...

Page 7: ...g of long PGN longer than 8 bytes converting output analog signals of automotive sensors to digital data SPN and their integration into Telematics system able to send more than 3000 operation Paramete...

Page 8: ...not require further processing on the Server changes of operational parameters of the object are continuously registered in nonvolatile memory data composition can be flexibly adjusted by user a choic...

Page 9: ...ng data for Report generation determining distance between points of the route recording movement direction angle change 8 Collection of analog signals processing signals from analog sensors filtering...

Page 10: ...nsforming to telematics SPN converting output analog signals of automotive s sensors to digital data SPN receiving signal form navigation satellites generating and sending Onboard reports to Server of...

Page 11: ...lematics information FMS and Telematics messages from sensors and peripheral equipment of Vehicle s standard CAN bus see figure 2 Figure 2 CAN UP 27 application within GPS GLONASS vehicle Telematics s...

Page 12: ...operate using S6 Technology and receive data from up to 8 DFM CAN fuel flow meters and up to 8 DUT E CAN fuel level sensors This is a convenient solution for fuel monitoring at stationary facilities d...

Page 13: ...27 online telematics gateway 1 pc 2 Sealing bar 1 pc 3 Specification 1 pc 4 S6 3 Mol power T connector with power wire 1 pc 5 Signal cable 2 m 1 pc 6 Mounting kit 1 pc including a fuse with holder 2...

Page 14: ...gy 5 CAN socket for connection to CANbus of Vehicle 6 SENS socket analog input for connecting signals voltage frequency discrete from analog sensors of Vehicle 7 green LED indicator PWR for power supp...

Page 15: ...ge range V from 9 to 45 Inbuilt battery ensures autonomous functioning without external power supply h not less than 5 Maximal current consumption at supply voltage 12 24 V mA not more than 100 50 Ave...

Page 16: ...cs gateway Operation manual Version 1 0 Technoton 2017 16 1 4 2 Data transfer protocol to Server CAN UP 27 sends information to the telematics Server AVL server in form of data packets according to GS...

Page 17: ...m S6 Database For Report generation you can choose any type of SPN except text To identify CAN UP 27 and other Units using S6 Technology you must specify the unique network addresses SA using the serv...

Page 18: ...AN UP 27 analog input signals specification Signal type measurement units Value Voltage V 0 30 Frequency kHz 0 001 10 Discrete V UPS 3 level 0 3 0 level 1 UPS voltage of power supply source Choosing t...

Page 19: ...chnical specifications of CAN UP 27 Technical specifications Overall dimensions CAN UP 27 online telematics gateway Operation manual Version 1 0 Technoton 2017 19 1 4 4 Overall dimensions Figure 7 CAN...

Page 20: ...ed to carefully study through the electrical circuit diagram and Operation manual for the Vehicle where CAN UP 27 is mounted For CAN UP 27 correct operation its mounting and configuration should be ca...

Page 21: ...GNSS it is necessary to provide a maximum view of the sky at place of CAN UP 27 mounting CAN UP 27 installation should be done in a dry location protected from aggressive impact of the environment CAN...

Page 22: ...IM card should be installed by qualified personnel Before installation it is recommended to disconnect external power of CAN UP 27 Insert SIM card contacts facing down into the Micro SIM slot of CAN U...

Page 23: ...isplayed and or made by Service CAN UP software see tables C 1 C 11 Service CAN UP allows remote configuration using service software and also CAN UP 27 s firmware update with SMS commands without cab...

Page 24: ...hnology the connector of service cable is connected to an appropriate free S6 connector Unit power supply is done through S6 cabling system see figure 9 b 2 Connect the adapter with USB cable to a fre...

Page 25: ...enables virtual COM port driver for it The virtual COM port will be displayed in the list of ports of Windows Device manager see figure 10 ATENTION It is recommended to untick power save check box for...

Page 26: ...escription LED Indicator Signal description Marking Status Light color POWER Red Power supply is on from vehicle electrical system Red Power supply is on from USB No signal Power supply is off or volt...

Page 27: ...cturing date and firmware version of the connected CAN UP 27 Horizontal menu provides the following Unit is connected disconnected Profile options loading profile saving profile and printing profile F...

Page 28: ...ad of entering Login and Password in Autorization fields Service CAN UP software will display password recovery code of the Unit see figure 13 This message is being sent to Technoton technical departm...

Page 29: ...e appeared Open window CAN_UP_ prf Load profile from Unit is used for loading profile from the connected CAN UP 27 Load default profile is used for loading profile with default factory settings With t...

Page 30: ...ll appear a notification on profile settings saving Pressing will save all the unsaved parameters and settings CAN UP 27 3 Print Profile Profile file can be saved on a PC disk in pdf format for later...

Page 31: ...connection PGN 63007 ATTENTION For GPRS settings contact service center of SIM card provider 3 Enter settings for CAN UP 27 connection with Server PGN 63068 IMPORTANT Data inserted into the fields of...

Page 32: ...able GSM connection to the remote Unit For connection to the remote CAN UP 27 make the following steps 1 In Horizontal menu of Service CAN UP software tick Remote connection field and press button see...

Page 33: ...P 27 to onboard electrical network of Vehicle use fuses from delivery set in accordance to scheme of connection Nominal fuse current is not more than 2 A 4 It is strongly recommended to lay CAN UP 27...

Page 34: ...erminating resistors to CAN UP 27 For safe connection of CAN UP 27 to automotive CAN bus it is recommended to use FMSCrocodile CCAN contactless FMS gateway see figure 18 Figure 18 Safe integration of...

Page 35: ...ing Wire Color Circuit Designation Signal Parameters SENS connector signal cable connector 1 KLIN Black K Line Digital ISO 14230 Standard 2 LLIN Green L Line 3 AIN White Analog signal input Analog vol...

Page 36: ...rdance with pin assignment of CAN socket as descried in table 7 Table 7 Connection of CAN connector Connector Pinout Connector Contact Number Wire Marking Wire Color Circuit Designation Signal Paramet...

Page 37: ...rts To create an Onboard report press button In Select triggering Event for create Report window select SPN of Event from Event drop down list see figure 20 Figure 20 Selecting Event for Onboard repor...

Page 38: ...uously in Report sending conditions area SPN 521151 11 1 you can enable or disable sending Report in roaming mode in the corresponding fields of Report Recipients area you can specify options of sendi...

Page 39: ...d SPN is contained and confirm the selection by pressing button For several SPNs which has the same ID number and are contained in one PGN you can find a qualifier in a tooltip by hovering a cursor ov...

Page 40: ...stalled in Telematics service ORF 4 see the document Telematics service ORF 4 User manual 2 To verify Online monitoring is working correctly via Vehicle telematics service ORF 4 see figure 24 Figure 2...

Page 41: ...when working with Service CAN UP software Ignition is turned on engine is running Regular operation mode No signal External power supply is off Battery is discharged GNSS Yellow Satellite receiver is...

Page 42: ...owing shape figure 25 Figure 25 CAN UP 27 packaging Label sticker with information on the product name certificates serial number firmware version manufacture date weight as well as Quality Control se...

Page 43: ...e stored in dry enclosed areas CAN UP 27 storage is allowed only in original packaging at temperature range from 50 to 40 C and relative humidity up to 100 at 25 C Do not store CAN UP 27 in the same r...

Page 44: ...closed transport that provides protection for CAN UP 27 from mechanical damage and precipitation When transporting by air CAN UP 27 must be stored in heated pressurized compartments Air environment in...

Page 45: ...1 0 Technoton 2017 45 6 Utilization re cycling CAN UP 27 does not contain harmful substances and ingredients that are dangerous to human health and environment during and after the end of life and rec...

Page 46: ...gateway Operation manual Version 1 0 Technoton 2017 46 Contacts Manufacturer Tel fax 375 17 240 39 73 JV Technoton www mastercan com http s6 jv technoton com ru E mail marketing technoton by Technical...

Page 47: ...if nothing NA is transmitted time SPN 959 960 961 Time in format HHMMSS in UTC if nothing NA is transmitted lat1 lat2 SPN 584 Latitude 5544 6025 N if nothing NA is transmitted NA lon1 lon2 SPN 585 Lon...

Page 48: ...ne symbol meaning of symbol B X Password of CAN UP 27 Numbers not less than 4 Y SA CAN UP 27 identification network address on the S6 bus Numbers not less than 4 Z Command Symbols 0 1 2 Z not less tha...

Page 49: ...internet Login 123 Pass 123 SAPN Save configurations of connection to mobile operator APN access point login password Example command B1111 100 SAPN 5 internet 123 123 Command value consists of the n...

Page 50: ...nning and Internet connection is established Example command B1111 100 CSRV 5 127 0 0 1 1234 Table B 3 Fields of SMS command LDFW Required fields Examples file_name File name and letter case should be...

Page 51: ...own functional and constructive features CAN UP 27 Standard characteristic wireless data transmission according to GSM standard Setting is not available for editing 521123 Line CAN UP No Name of the p...

Page 52: ...to 20 For each saved malfunction is indicated following faulty nod malfunction name malfunction counter This setting allows to monitor CAN UP 27 working performance In case of lack of saved malfunctio...

Page 53: ...e fact year 1985 2235 Present date year Used during Events registration Present time is available for user for editing manually or synchronizing of date time with computer clock By default time is set...

Page 54: ...ehicle power supply status PGN 63089 521055 Vehicle Power Supply Voltage On the fact V 0 3212 75 Shows current value of ON voltage 521055 2 9 Vehicle Power Supply Voltage 2 9 Average For 5 Minutes On...

Page 55: ...ower supply On the fact s 0 4211080000 Counter of total operating time of Vehicle from onboard network since CAN UP 27 installation to the Vehicle User cannot reset the value of this counter 521172 Ve...

Page 56: ...ime according to GNSS On the fact s 0 4211080000 This setting displays present time in UTC format defined according to GNSS data 584 Latitude On the fact Degree 210 211 101 This setting displays geogr...

Page 57: ...tween points on the straight section of Vehicle s movement for sending the Report 521079 Angle of change course 5 00 Degree 0 360 Field for entering Vehicle s course change angle which if exceeded tri...

Page 58: ...Report formation in roaming mode 521154 25 0 Send Report 25 0 AVL On No On Off Field for enabling or disabling sending Report to Server 521154 25 1 Send Report 25 1 E mail Off No On Off Field for enab...

Page 59: ...ending Reports accumulated in internal memory while Vehicle was outside of network operator s coverage to the Server FIFO First In First Out sending accumulated Reports in chronological sequence i e s...

Page 60: ...entification at AVL Server Fields of entered prefix have to match with the settings of Unique ID field while registering vehicle at ORF4 Telematics Server see User manual 521621 13 2 Password 13 2 AVL...

Page 61: ...nfiguration of CAN UP 27 521148 Number of SMS sent errors On the fact pcs Counter of sent SMS command errors for remote configuration of CAN UP 27 521149 Number of GPRS modem resets On the fact pcs Co...

Page 62: ...manual Version 1 0 Technoton 2017 62 9 Collector 1A1F1D FM used for receiving and transformation of analog frequence discrete signal to digital values of SPN parameters Figure C 2 Collector 1A1F1D FM...

Page 63: ...calibration table for input 1 By default the table contains two points corresponding to extreme values of the range in which input signal is changing Maximum of 10 calibration points can be saved In...

Page 64: ...of discrete physical input of CAN UP27 521150 PGN 64960 Passenger counter No 0 65535 Enter output PGN which will contain SPN parameter converted from discrete signal PGN can be selected through Servic...

Page 65: ...ton 2017 65 10 Axles Load Monitoring FM designed for obtaining real time data on current Vehicle load per axle total trip and operation time in different modes of axle load Events of loading unloading...

Page 66: ...r can be reset by user 521057 10 1 Vehicle working time 10 1 Empty On the fact s 0 4211080000 Displays total time of Vehicle in operation mode corresponding to axle load with unloaded semi trailer The...

Page 67: ...mportant Events up to 15 Important events are electrical network is defective panic button pressed Each Event is indicated with name date time and also additional information if its available Evets ar...

Page 68: ...ploading into CAN UP 27 memory will appear In case of any errors the Software will send warning message To cancel firmware upgrade it is needed to press button ATTENTION Before the end of the update p...

Page 69: ...gy example of wiring diagram CAN UP 27 online telematics gateway Operation manual Version 1 0 Technoton 2017 69 Annex E CAN UP 27 using S6 Technology example of wiring diagram Figure E 1 Connectin Uni...

Reviews: