Annex C SPN of CAN UP 27 Functional modules
CAN UP 27 online telematics gateway. Operation manual. Version 1.0
© Technoton, 2017
54
3)
Vehicle power supply FM
— is designed for monitoring of onboard power network voltage,
current mode of power network, operation time of Vehicle in different power network modes,
quantity of engine starts
*
, exceeding permissible time of continuous operation of starter
*
.
*
Currently not supported.
Figure C.1 — Operation modes on onboard network (ON) voltage level
Table C.3 — Vehicle power supply FM. Displayed and/or editable SPN
with the help of Software Service CAN UP
SPN
Name
Factory
value
Unit of
measure
Range
Clarification
Vehicle power supply status
PGN 63089
521055
Vehicle Power
Supply Voltage
On the fact
V
0…3212.75
Shows current value of ON voltage.
521055
/2.9
Vehicle Power
Supply
Voltage/
2.9 Average
For 5 Minutes
On the fact
V
0…3212.75
Shows average value of ON voltage within previous
5 minutes.
521056
Vehicle Power
Supply Status
On the fact
No
Off/
Lowe level/
Accumulator/
Starter/
Generator/
High level
Shows current mode of ON in accordance with user-defined
borders of ON voltage levels of Vehicle (see figure C.1).
521076
Vehicle Power
Supply
Presence
On the fact
No
On/Off
Displays the current state of the board (On/Off) in
accordance with the user-set voltage level of the TC system
trip (see figure C.1).
Power supply borders
PGN 63067
521075
Nominal
Battery
Voltage
24
V
0…60
Field for entering a nominal value of accumulator voltage of
Vehicle (U
nom
=12V/24V).