Receipt and site selection 

Carefully remove the UPS from its packaging, and carry out a meticulous inspection. We recommend keeping the 
original  packaging  in  a  secure  place,  in  case  you  need  to  send  the  UPS  for  maintenance  purposes.  In  case  of 
transport damage, notify the carrier and dealer immediately.  

We recommend paying attention to the below points in order to choose a correct placement for your UPS: 

 

The  UPS  is  designed  to  operate  in  a  protected  environment  (e.g.  offices).  We  therefore  recommend 
installing it in a place with very little or no humidity, dust or smoke.  

 

In  all  circumstances,  see  the  “Technical  Characteristics”  chapter  for  environmental  specifications  and 
check that the selected area meets these specifications. 

 

During normal operation the UPS discharges a minimal amount of heat. So it is necessary to leave at least 
20 cm of unobstructed space all around the UPS in order to keep it properly ventilated. 

 

Do not obstruct ventilation holes. 

 

Do not insert objects or pour liquids in the ventilation holes. 

 

Do not rest any object on top of the UPS. 

 

Do not keep liquids, flammable gases or corrosive substances near the unit.  

 

Install the UPS on a properly tiled floor. Avoid the installation on a floor that is not tiled flat. 

Summary of Contents for ECO 0.50

Page 1: ...Uninterruptible Power Supply ECO 0 50 ECO 0 70 ECO 0 90 ECO 1 1 ECO 1 3 User s manual...

Page 2: ......

Page 3: ...8 Maintenance 10 8 1 UPS Cleaning 10 8 2 Battery 10 8 3 Battery Replacement 10 8 4 Operator Safety 11 9 Troubleshooting 12 Conformity to the European Directives 13 Product Disposal 13 Lead Batteries 1...

Page 4: ...the batteries they will remain powered and therefore dangerous even after the UPS has been disconnected from AC power mains Before any repair or maintenance work disconnect the batteries by removing t...

Page 5: ...ns for the operator for the UPS correct installation and gives useful advice on the product and battery maintenance For any type of problem please refer to this manual before calling the customer serv...

Page 6: ...signed to operate in a protected environment e g offices We therefore recommend installing it in a place with very little or no humidity dust or smoke In all circumstances see the Technical Characteri...

Page 7: ...there are see figure 1 1 The ON OFF button enables the user to turn ON OFF the UPS 2 The LINE BATTERY led this led blue color is always on during the functioning in Normal Mode it flashes one time eve...

Page 8: ...the UPS 2 Connect the UPS Input socket to the AC line outlet through the Personal Computer supplying cable It is mandatory to ground the AC line outlet according to the Safety Standards Carefully che...

Page 9: ...t point 3 The batteries reach the 90 of their capacity after about 4 hours of recharge It is compulsory to ground earth the UPS according to the Safety Standards Risk of electric shock at the Output l...

Page 10: ...ing the batteries from discharging excessively the UPS stops supplying Output power deactivates control panel indication and goes to a waiting state Once AC Input comes back on the UPS restarts automa...

Page 11: ...Single phase 230 Vac Output Voltage Regulation Normal mode As Input Output Voltage Regulation Battery mode 5 Output Inverter Waveform Modified Sinewave Accepted Overload 130 Certifications CE Standar...

Page 12: ...onth Take in mind that batteries are recharged automatically if the UPS works in Normal mode or if the UPS is off and connected to the AC Input Line Battery life strongly depends on the ambient temper...

Page 13: ...ay tools or metal parts on top of batteries e Disconnect the charging source prior to connecting or disconnecting battery terminals f Determine if battery is inadvertently grounded If inadvertently gr...

Page 14: ...remain powered and therefore dangerous even after the UPS has been disconnected from AC power mains Before any repair or maintenance work disconnect the batteries by removing the positive cable red c...

Page 15: ...urban waste but must be treated as a separate waste Any violation is indictable with financial sanctions as per in force regulations An incorrect waste disposal or an improper use of the same or of a...

Page 16: ...TECNOWARE s r l www tecnoware com...

Reviews: