UPS ERA LED 1.5 – 2-0 – 2.6 

3

 

User’s manual 

 

1

 

Introduction 

ERA  LED  is  a  Line  Interactive  UPS  (Uninterruptible  Power  Supply)  specifically  designed  to  protect  your  computer 
from  any  type  of  irregularities  in  the  AC  line  (such  as  black-outs,  under  or  over  voltages,  micro-interruptions), 
which often cause damage to your Hardware and Software. 

Under  normal  AC  line  condition,  ERA  LED  performs  output  voltage  regulation  and  filters  frequently  occurring 
electrical  disturbances  (such  as  transients,  spikes,  interferences,  etc.),  thus  protecting  all  devices  connected  to 
the  outlets,  and  recharging  the  batteries  in  an  ideal  way.  In  case  of  anomaly  to  the  AC  line,  the  UPS  continues 
feeding the protected equipment.   

ERA  LED  is  equipped  with  USB  interface  which  can  be  used  to  notify  a  power  failure  or  a  low  battery  condition 
directly to a computer: this makes it possible to automatically save your data during an extended black-out with 
the most widespread operating systems (Windows, Mac OS X, Linux, etc.). 

 

 

Read  this  manual  carefully  before  using  the  ERA  LED;  it  includes  important  safety 
warnings and useful advices for correct use and installation. 

This manual is a guide that enables you to correctly install and use your ERA LED. This 
manual  includes  important  SAFETY  instructions  for  the  operator,  for  the  UPS  correct 
installation,  and  gives  useful  advice  on  the  product  and  battery  maintenance.  For  any 
type of problem, please refer to this manual before calling the customer service. 

 

ERA  LED  is  constantly  being  developed  and  improved:  consequently,  your  unit  may  differ  somewhat  from  the 
description contained in this manual.  

This manual includes the following models: 

 

ERA LED 1.5 (1.5 KVA) 

 

ERA LED 2.0 (2.0 KVA) 

 

ERA LED 2.6 (2.6 KVA) 

 

In this manual ERA LED will simply be referred to as UPS. 

Summary of Contents for ERA LED 1.5

Page 1: ...Uninterruptible Power Supply ERA LED 1 5 ERA LED 2 0 ERA LED 2 6 User s manual...

Page 2: ......

Page 3: ...Characteristics 11 9 Maintenance 12 9 1 UPS Cleaning 12 9 2 Battery 12 9 3 Battery Replacement 12 9 4 Operator Safety 13 10 Troubleshooting 14 Conformity to the European Directives 15 Product Disposal...

Page 4: ...he batteries they will remain powered and therefore dangerous even after the UPS has been disconnected from AC power mains Before any repair or maintenance work disconnect the batteries by removing th...

Page 5: ...low battery condition directly to a computer this makes it possible to automatically save your data during an extended black out with the most widespread operating systems Windows Mac OS X Linux etc R...

Page 6: ...3 Receipt and site selection Carefully remove the UPS from its packaging and carry out a meticulous inspection We recommend keeping the original packaging in a secure place in case you need to send th...

Page 7: ...front panel informs the user about operating status alarm conditions and measurements Front panel shown below consists of two parts 1 3 Leds that show the functioning modes alarm and fault conditions...

Page 8: ...e 2 Figure 2 LCD Display 1 Line LED this blue led is always on in LINE mode 2 Battery LED this yellow led is on in BATTERY mode 3 Fault LED this FAULT led red switches on to indicate the excessive or...

Page 9: ...OUT connectors to protect and filter a phone line an ADSL or a LAN TNV 3 type connections 6 Computer Interface USB connector it is the communication USB port The 2 ONLY FILTERED Output receptacles red...

Page 10: ...at the UPS do not go in overload status otherwise it is necessary to remove part of the Output load 7 Simulate a black out by removing the AC Input line The UPS starts working in Battery mode the Line...

Page 11: ...Battery Led in yellow color and by an acoustic signal every 10 seconds 6 3 Low Battery and Automatic Restart In Battery mode ERA LED indicates the Low Battery condition whenever the battery reaches a...

Page 12: ...apter Technical Characteristics as this may damage the unit In this case the warranty is void 6 5 Fault Condition The UPS indicates the Fault condition by LCD display by lighting of the Fault led and...

Page 13: ...Accepted Overload 130 Certifications CE Standards CEI EN 62040 1 2009 Low Voltage Directive CEI EN 62040 2 2006 EMC Directive Efficiency 92 Battery Type Lead acid sealed free maintenance Number of bat...

Page 14: ...ake in mind that batteries are recharged automatically if the UPS works in Normal mode or if the UPS is off and connected to the AC Input Line Battery life strongly depends on the ambient temperature...

Page 15: ...tools or metal parts on top of batteries e Disconnect the charging source prior to connecting or disconnecting battery terminals f Determine if battery is inadvertently grounded If inadvertently groun...

Page 16: ...colour from the positive pole of the battery ANOMALY POSSIBLE CAUSE ACTION TO SOLVE The UPS does not turn on ON OFF button Press the ON OFF button and check that is pushed Batteries are flat Recharge...

Page 17: ...rban waste but must be treated as a separate waste Any violation is indictable with financial sanctions as per in force regulations An incorrect waste disposal or an improper use of the same or of any...

Page 18: ......

Page 19: ......

Page 20: ...TECNOWARE s r l www tecnoware com...

Reviews: