www.techsys.com.au
Version 1.3 11/12/11
48
C o r p o r a t io n
SPECIFICATIONS
Item
Description
Power supply
Control
- 240VAC 50-60Hz single phase
2 amp Single pole circuit breaker protected
Optional Supply.
- 24 VDC- 200mA min 500mA max (3pumps)
750mA max (6pumps).
- 24 VAC- 200mA min 500mA max (3pumps)
750mA max (6pumps).
External transducer power
supply
24 VDC- 100mA max. Auto reset fuse
protected
EMC/ EMI filtering
Designed to minimize conducted and radiated
emissions.
Standard Transducer
0-250mV
4% accuracy uncompensated.
0-250 psi operating range
Temp max 50 degC
500 psi burst pressure
Temperature compensated
Time based functions
5% of real time
Output Relays
5 amp 250VAC changeover
software configurable
Switched inputs
Voltage free - internal supply 24VDC - read
threshold - 2mA
Operating temperature
0 to 50 degC
Over voltage protection
Varistor protection
Clamp voltage 275V - 4500 amps
1 amp - IEC127-2/3
Enclosure
IP54 not certified
Contactor
Rated voltage - 690Vac
Coil - as per control Voltage
cycles mech. - 10x 10
6
elec. - 2 x 10
6
cycles/hr - 3600
auxiliary contacts - 1 x NO
Standard - IEC947
Motor circuit breakers
Standard - IEC947
– Start current 10x FLC
Wiring
Standard - AS3000
Input supply Voltage - 3 phase
230 - 440V
Input supply tolerance - 3
phase
-20% + 10%
Input frequency range
48 to 62 Hz