UPS ERA LCD  0.65 – 0.85 – 1.1 Rack Mount 

 
 

 

 

 

 

 

Battery  replacement  must  be  performed  exclusively  by  qualified  technical  personnel 
authorized  by  TECNOWARE.  TECNOWARE  declines  any  responsibility  if  this  warning  is 
disregarded. 

When replacing batteries, replace with the same type and number. 

CAUTION: A battery can present a risk of electrical shock and high short circuit current. 
The following precautions should be observed when working on batteries: 

a)

 

Remove watches, rings or other metal objects; 

b)

 

Use tools with insulated handles; 

c)

 

Wear rubber gloves and boots; 

d)

 

Do not lay tools or metal parts on top of batteries; 

e)

 

Disconnect  the  charging  source  prior  to  connecting  or  disconnecting  battery 
terminals; 

f)

 

Determine  if  battery  is  inadvertently  grounded.  If  inadvertently  grounded,  remove 
source from ground. 

CAUTION: Do not dispose of batteries in a fire. The batteries may explode. 

CAUTION: Do not open or mutilate batteries. Released electrolyte is harmful to the skin 
and eyes. It may be toxic. 

 

9.4

 

Operator Safety 

Whenever the UPS is not responding anymore to original characteristics, the UPS must be made non-operative and 
every usage not authorised must be avoided. After it will be necessary to refer to qualified technical personnel. 

Original safety characteristics might not be if, for example, the UPS has visible damage or irregular operation. 
 
 

10

 

Troubleshooting 

Alarms  and  problems  you may encounter during operating the UPS are given in the table below. 

Apply 

the suggestions corresponding to each anomaly as described into the table.  

If  your  anomaly  is  excluded  or  the  suggested  actions  do  not  solve  your  problem,  consult  the  Technical  Service. 
Please give the following information to the Technical Service: 

 

Model and serial number of the UPS, which can be found on the nameplate on the rear of the UPS.  

 

Description of anomaly. 

Summary of Contents for ERA LCD 0.65 Rack Mount

Page 1: ...Supply ERA LCD 0 65 Rack Mount ERA LCD 0 85 Rack Mount ERA LCD 1 1 Rack Mount User s manual U T E Electronic GmbH Co KG Friedrich Ebert Str 112a 58454 Witten Germany Tel 02302 282830 Email info ute d...

Page 2: ...rst Start Up 7 6 Functioning 8 6 1 Normal Mode 8 6 2 Battery Mode 8 6 3 Low Battery and Automatic Restart 8 6 4 Load Control 8 6 5 Fault Condition 9 7 Communication Interface 9 8 Technical Characteris...

Page 3: ...main powered and therefore dangerous even after the UPS has been disconnected from AC power mains Before any repair or maintenance work disconnect the batteries by removing the positive cable red colo...

Page 4: ...low battery condition directly to a computer this makes it possible to automatically save your data during an extended black out with the most widespread operating systems Windows Linux etc Read this...

Page 5: ...y Maximum reliability Smart design and easy to use 3 Receipt and site selection Carefully remove the UPS from its packaging and carry out a meticulous inspection We recommend keeping the original pack...

Page 6: ...ditions and measurements Front panel shown below consists of two parts 1 LCD display provides information about input only in line mode and output voltage output frequency only in battery mode battery...

Page 7: ...oltage 3 BATTERY LEVEL 3 digits indicate the battery charging percentage 4 LOAD LEVEL 3 digits indicates the output load percentage 5 FREQUENCY the 3 digits indicate the output frequency only visualiz...

Page 8: ...IEC C13 type black colour to supply critical loads 3 Telephone protection RJ11 IN OUT connectors to protect and filter a phone line TNV 3 type connections 4 Computer Interface DB9 female connector it...

Page 9: ...eover be sure that all the devices connected to the UPS outputs are working correctly By LCD display check if the Output load percentage is less than 100 otherwise it is necessary to remove part of th...

Page 10: ...matically thus preventing the batteries from discharging excessively the UPS stops supplying Output power deactivates control panel indication and goes to a waiting state Once AC Input comes back on t...

Page 11: ...e UPS rear side there are the connectors of the Interfaces Only one of the RS232 USB communications can be activated at one time To activate RS232 communication it is sufficient to connect the RS232 c...

Page 12: ...Voltage Directive CEI EN 62040 2 2006 EMC Directive Efficiency 92 Battery Type Lead acid sealed free maintenance Number of batteries 1 Nominal Battery Voltage 12 Vdc Battery Specifications 12 Vdc 7 Ah...

Page 13: ...nd that batteries are recharged automatically if the UPS works in Normal mode or if the UPS is off and connected to the AC Input Line Battery life strongly depends on the ambient temperature There are...

Page 14: ...CAUTION Do not dispose of batteries in a fire The batteries may explode CAUTION Do not open or mutilate batteries Released electrolyte is harmful to the skin and eyes It may be toxic 9 4 Operator Safe...

Page 15: ...Service The UPS always function in Battery mode Input mains power cable is disconnected Check the input mains power cable Check the presence of the electrical mains ON OFF switch Check if the rear ON...

Page 16: ...disposed as an urban waste but must be treated as a separate waste Any violation is indictable with financial sanctions as per in force regulations An incorrect waste disposal or an improper use of t...

Reviews: