UPS ERA LCD  0.65 – 0.85 – 1.1 Rack Mount 

 

4.2

 

Rear Side 

 

 

 

Figure 3 – Rear Side 

 

1.

 

Grounded AC Input power socket with input fuse: 

IEC C14 type; to connect the UPS to the AC utility line. 

Fuse electrical specification: max current 6A (EXA 1.1–1.5 Rack Mount), max current 8A (EXA 2.2 Rack Mount) 
or max current 10A (EXA 2.6-3.2 Rack Mount),  voltage 250 V.

 

2.

 

Grounded UPS Output receptacles: 

IEC C13 type, black colour, to supply critical loads.

 

3.

 

Telephone  protection  (RJ11  IN/OUT  connectors): 

to  protect  and  filter  a  phone  line  (TNV-3  type 

connections). 

4.

 

Computer Interface (DB9 female connector

)

:

 it is the communication RS-232 port. 

5.

 

Computer Interface (USB connector

)

:

 it is the communication USB port. 

6.

 

ON/OFF button: 

to active the AC utility line. 

 

 

In  case  of  anomaly  to  the  AC  line  (black-out),  ONLY  the  UPS  Output receptacles (black 
colour,  #2)  continue  supplying  the  correct  power  to  all  connected  equipment.  Please 
connect all the non-critical devices to the UPS Output receptacles. 

 

Summary of Contents for ERA LCD 0.65 Rack Mount

Page 1: ...Supply ERA LCD 0 65 Rack Mount ERA LCD 0 85 Rack Mount ERA LCD 1 1 Rack Mount User s manual U T E Electronic GmbH Co KG Friedrich Ebert Str 112a 58454 Witten Germany Tel 02302 282830 Email info ute d...

Page 2: ...rst Start Up 7 6 Functioning 8 6 1 Normal Mode 8 6 2 Battery Mode 8 6 3 Low Battery and Automatic Restart 8 6 4 Load Control 8 6 5 Fault Condition 9 7 Communication Interface 9 8 Technical Characteris...

Page 3: ...main powered and therefore dangerous even after the UPS has been disconnected from AC power mains Before any repair or maintenance work disconnect the batteries by removing the positive cable red colo...

Page 4: ...low battery condition directly to a computer this makes it possible to automatically save your data during an extended black out with the most widespread operating systems Windows Linux etc Read this...

Page 5: ...y Maximum reliability Smart design and easy to use 3 Receipt and site selection Carefully remove the UPS from its packaging and carry out a meticulous inspection We recommend keeping the original pack...

Page 6: ...ditions and measurements Front panel shown below consists of two parts 1 LCD display provides information about input only in line mode and output voltage output frequency only in battery mode battery...

Page 7: ...oltage 3 BATTERY LEVEL 3 digits indicate the battery charging percentage 4 LOAD LEVEL 3 digits indicates the output load percentage 5 FREQUENCY the 3 digits indicate the output frequency only visualiz...

Page 8: ...IEC C13 type black colour to supply critical loads 3 Telephone protection RJ11 IN OUT connectors to protect and filter a phone line TNV 3 type connections 4 Computer Interface DB9 female connector it...

Page 9: ...eover be sure that all the devices connected to the UPS outputs are working correctly By LCD display check if the Output load percentage is less than 100 otherwise it is necessary to remove part of th...

Page 10: ...matically thus preventing the batteries from discharging excessively the UPS stops supplying Output power deactivates control panel indication and goes to a waiting state Once AC Input comes back on t...

Page 11: ...e UPS rear side there are the connectors of the Interfaces Only one of the RS232 USB communications can be activated at one time To activate RS232 communication it is sufficient to connect the RS232 c...

Page 12: ...Voltage Directive CEI EN 62040 2 2006 EMC Directive Efficiency 92 Battery Type Lead acid sealed free maintenance Number of batteries 1 Nominal Battery Voltage 12 Vdc Battery Specifications 12 Vdc 7 Ah...

Page 13: ...nd that batteries are recharged automatically if the UPS works in Normal mode or if the UPS is off and connected to the AC Input Line Battery life strongly depends on the ambient temperature There are...

Page 14: ...CAUTION Do not dispose of batteries in a fire The batteries may explode CAUTION Do not open or mutilate batteries Released electrolyte is harmful to the skin and eyes It may be toxic 9 4 Operator Safe...

Page 15: ...Service The UPS always function in Battery mode Input mains power cable is disconnected Check the input mains power cable Check the presence of the electrical mains ON OFF switch Check if the rear ON...

Page 16: ...disposed as an urban waste but must be treated as a separate waste Any violation is indictable with financial sanctions as per in force regulations An incorrect waste disposal or an improper use of t...

Reviews: