33
4. Technical Data
5. Cleaning, Maintenance and Storage
5.1 Tests
•
Regular maintenance work is necessary to ensure the proper and long-lasting function of
the unit.
•
Be sure to observe the prescribed maintenance intervals.
Concrete vibrators are to be installed according to the conditions of use and the operational
conditions.
The examination results shall be recorded in writing and kept at least until the next examination.
5.2 Maintenance
•
Maintenance work may only be carried out on concrete vibrators if these are approved
by the mains are disconnected.
•
Before maintenance work, ensure that the concrete vibrator is not unintentionally
can be plugged in.
•
Do not use the unit when maintenance or repairs are necessary.
•
After maintenance work, guards must be properly refitted.
Model
TMX concrete vibrator TBR 2000
Concrete vibratr
Power
2000 W
Voltage
230 V
Frequency
50 Hz
Material
Plastic, Steel
Speed
4000 RPM
Vibrating bottle
Ø Vibrating head
approx. 45 mm
Ø Rubber hose
approx. 32 mm
Ø Flexible shaft
approx. 12 mm
Length
approx. 6 m
Total weight
approx. 25 kg
Summary of Contents for TBR 2000
Page 2: ...2 ...
Page 56: ...56 Explosionszeichnung Exploded drawing Vue explosée ...
Page 58: ...58 Notizen Notes Notes ...