8.3
INFORMATION REGARDING THE MODE OF OPERATION
FIGURE 16: Do not rip
•
Do not operate the hydraulic breaker for more than 30 seconds at the same point without the
tool penetrating. It can lead to overheating and damage the tool tip. Search for a suitable
point where the tool can penetrate, e.g. a weak spot in the material.
•
Do not rotate the support frame such that you take support of the tip.
•
Keep the hydraulic breaker in a perpendicular position for at least one minute after every working
hour if the hydraulic breaker has been operated in a horizontal position or upside-down position.
This allows stones to come out from the bush for instance.
FIGURE 17: Do not rotate the support frame by the tip
OPERATING MANUAL
-
H
ydraulic
breakers
T
series
29
/44
REV
0.0
OPERATION
8