S.p.A.
ITEM TE550
Instruction manual
PRESSURE RATIO
This parameter can be used to select the optimum bar/Volt ratio for the type of proportional
solenoid valve that is to be employed. It works only if the PROP. VALVE parameter is
enabled. Further pieces of information are described in the paragraph
INTERFACE FOR
PROPORTIONAL VALVE.
AUTORETAIN
This parameter allows disabling the cycle start signal AUTORETAIN.
The welding time is always completed whenever the value is set to ON.
By setting the parameter to OFF, the working cycle is stopped the moment the cycle start
signal is disabled and does not complete the welding time. This occurs even if the welding
current is in its flowing phase. This function is specifically to be used when the machine works
with mechanical devices instead of pneumatic ones.
When the AUTORETAIN parameter is set to OFF, the following question is asked:
- by pressing the key any time the spot performed is not accomplished, but it has
been interrupted during the welding time, the message error 118 has been displayed;
RELEASE MESSAGE?
KEY[+]=YES KEY[-]=NO
- by pressing the key , instead, the display of the same message is cancelled.
NC CONTACTS
This parameter activates the normally closed inputs of the cycle start signal, allowing the weld
cycle start. However, this is possible only if the exchange double contact is present. This
contact would enable the following operation: the normally open contact would close while the
normally closed one would open up.
At present, this function is always on OFF and, therefore, it is disabled.
SEAM WELD MODE
By means of this parameter, it is possible to enable the function for adjusting the control unit
to the seam welders’ specifications.
Further pieces of information are described in the paragraph
SEAM WELD MODE
.
BUTT WELD MODE
By means of this parameter, it is possible to enable the function for adjusting the control unit
to the butt welders’ specifications.
Further pieces of information are described in the paragraph
BUTT WELD MODE
.
SER. SPOT MODE
By means of this parameter, it is possible to enable the function for adjusting the control unit
to the high speed spot welders.
Further pieces of information are described in the paragraph
SER. SPOT MODE
.
CASCADE MODE
This parameter allows reversing the outlet signal of the end cycle (END), that is to say from
normally open contact to normally closed contact, so to allow putting in cascade more control
units. Check the proper paragraph for further information.
ADJUST POWER%
This parameter allows modifying the weld switch-on delay time for correcting the power map
and adjusting the control unit to the transformer it is connected to.
45/92