S.p.A.
ITEM TE550
Instruction manual
79/92
The control unit prints the heading and the value of the parameters of the selected program,
when turned on and each time the key selector is switched from PROGRAM to RUN position.
Data print example during the weld in WORKING MODE = IK:
PROG CYCLES CURRENT DEGREE ENERGY SPOTS LIMIT THICK IDENT PRES
001 10,0 08.00 061 00000 00001 ----- 00.000 0.000 00.0
001 10,0 07.90 061 00000 00002 ----- 00.000 0.000 00.0
001 10,0 07.90 061 00000 00003 ----- 00.000 0.000 00.0
001 10,0 07.97 061 00000 00004 ----- 00.000 0.000 00.0
Data print example during the weld in CONTROL MODE = CUR:
PROG CYCLES CURRENT DEGREE ENERGY SPOTS LIMIT THICK IDENT PRES
001 10,0 06.00 062 00000 00009 CUR OK 00.000 0.000 00.0
001 10,0 06.00 062 00000 00010 CUR OK 00.000 0.000 00.0
001 10,0 06.00 062 00000 00012 CUR MIN 00.000 0.000 00.0
001 10,0 06.00 062 00000 00013 CUR MIN 00.000 0.000 00.0
001 10,0 06.00 062 00000 00014 CUR MAX 00.000 0.000 00.0
001 10,0 06.00 062 00000 00015 CUR MAX 00.000 0.000 00.0
Data print example during the weld in CONTROL MODE = DEG:
PROG CYCLES CURRENT DEGREE ENERGY SPOTS LIMIT THICK IDENT PRES
001 10,0 06.00 062 00000 00009 DEG OK 00.000 0.000 00.0
001 10,0 06.00 062 00000 00010 DEG OK 00.000 0.000 00.0
001 10,0 06.00 062 00000 00012 DEG MIN 00.000 0.000 00.0
001 10,0 06.00 062 00000 00013 DEG MIN 00.000 0.000 00.0
001 10,0 06.00 062 00000 00014 DEG MAX 00.000 0.000 00.0
001 10,0 06.00 062 00000 00015 DEG MAX 00.000 0.000 00.0
Print example of the work program parameters values:
WELD CONTROL UNIT TE550 REV. 3.31
PROGRAM N.
001
WORKING MODE
IK
CONTROL MODE
NO
SQUEEZE 1
10.0
SQUEEZE 20.0
PRESSURE bar
05.0
FORGE DELAY
00
FORG.PRESS. bar
07.0
PRE-WELD 00.0
PRE-POWER %
05
COLD 1
00
SLOPE UP.
00
WELD 05.0
CURRENT kA
05.0
IMPULSE N.
01
COLD 2
01
SLOPE DOWN.
00
COLD 3
00
POST-WELD 00.0
POST-POWER %
05
HOLD TIME
10.0
OFF TIME
00.0