background image

Keep these important operatin instructions.

Check www.tecnare.com for updates

DMA 8X8

DSP MATRIX

Operation Manual

Commercial Series

Summary of Contents for ARRAY Series

Page 1: ...Keep these important operatin instructions Check www tecnare com for updates DMA 8X8 DSP MATRIX Operation Manual Commercial Series ...

Page 2: ......

Page 3: ...ny errors or inaccuracies that may appear in this manual or the products and software described in it Technical specifications dimen sions weights and properties do not represent guaranteed qualities As manufacturers we reserve the right to make alterations and modifications within the framework of legal provisions as well as changes aimed at improving quality EXEL ACOUSTICS SL CL Encinar 282 Pol ...

Page 4: ...ime 13 Refer all servicing to qualified service personnel Ser vice is required when the apparatus has been dam aged in any way such as power supply cord or plug damaged liquid has been spilled or objects have fallen into the apparatus this apparatus has been ex posed to rain or moisture does not operate normally or has been dropped 14 Use the mains plug to disconnect the device from mains 15 Do no...

Page 5: ... LA CONEXIÓN A TIERRA NO DEBE DESCO NECTARSE EN NINGUNA CIRCUNSTANCIA 11 Proteja el cable de alimentación de ser pisado o aplastado especialmente los enchufes receptáculos y en el punto en el que salen del aparato 12 Desconecte este aparato durante tormentas eléctri cas terremotos o cuando no vaya a emplearse du rante largos periodos 13 Confíe las reparaciones a personal cualificado Se requiere se...

Page 6: ...s warning Non compliance can lead to serious injury or death Este símbolo indica Riesgo de lesiones Es fundamental observar esta advertencia Su incumplimiento puede provocar lesiones graves o la muerte This simbol indicate Personal injuries It is essential to observe this warning Non compliance can lead to minor or slight injury Este símbolo indica Lesiones personales Es fundamental observar esta ...

Page 7: ...LATION It must be fitted in to a 19 rack enclosure and not operated unless so installed The rack enclosure should be open at the front and back to allow free ven tilation and movement of air through the product DECLARATION OF CONFORMITY WITH FCC RULES We EXEL Acoustics SL CL Encinar 282 Pol Ind Monte Boya 45950 Casarrubios del Monte Toledo España declare under our sole responsibility that this fam...

Page 8: ...e avec un noyau vert ou vert jaune qui doit être relié à la borne de terre de connecteur d alimentation ou la borne de terre de l installation Le cordon doit être un maximum de 6 2m de long 14 AWG 2 5mm2 CSA être classé SJ SJT SJE ou 300 500V H05W F et être marquée VW 1 THIS PRODUCT IS DESIGNED FOR PERMANENT INSTALLATION It must be fitted in to a 19 rack enclosure and not operated unless so instal...

Page 9: ...ctives 1 Directiva de Baja Tensión 2014 35 UE 2 Directiva de Compatibilidad Electromagnética 2014 30 UE 3 Directiva RoHS 2011 65 UE 4 Directiva RAEE 2012 19 UE 1 Low Voltage Directive 2014 35 EU 2 EMC 2014 130 EU 3 RoHS Directive 2011 65 EU 4 WEEE Directive 2012 19 EU Y es conforme a las siguientes Normas Armonizadas Europeas In compliance with these Harmonized European Norms 1 EN60065 8th Audio v...

Page 10: ...res________________________________________ 12 2 3 Front and Rear Panel_________________________________ 13 3 Connections_________________________________________________ 14 3 1 Audio Input Connections______________________________ 14 3 2 Audio Output Connections_____________________________ 14 3 3 Audio Wiring Reference_______________________________ 14 3 4 ETEHERNET port for programming and cont...

Page 11: ...ble on the Tecnare website http www tecnare com Tecnare Technical Support is available at T 34 918 170 110 34 918 171 001 e mail support tecnare com Thank you again for placing your confidence in Tecnare products 1 2 Unpacking After unpacking the unit please check carefully for damage Every Tecnare product is tested and inspected before leaving the factory and should arrive in perfect condition If...

Page 12: ... so that the Integrator can edit it or the on site technicians or end users who have no idea of relevant techniques can operate it Superior safety functions make it possible for the end users to access to the controls allowed by the engi neer or designer 2 2 Key features DANTE network audio optional Network TCP IP control can realize management of multiple devices 8 balanced MIC LINE inputs indepe...

Page 13: ...ctor a GPIO for 0 5 Vdc continuous control voltage RS 232 RS485 port USB audio port and Power connector Fig 3 Rear panel Main socket 230 Vac 50Hz 40W Ethernet Connector RJ45 10 100 Base T Ethernet connector is used for IP based PC Software and host and third party accessory controller GPIO 6 bit 3 81mm terminal 4 input output contacts to be assigned to different functions RS 485 Used as serial com...

Page 14: ...logue MIC LINE inputs It features a couple of re movable balanced 12 pin Phoenix terminal strips Unit gain 0dB is set through volume control and the analogue output section is corrected to 4dBu with 20dB headroom That is to say 0dBFS digital signal is equivalent to 24dBu output signal If other signal levels are required you may change the volume to achieve it 3 3 Audio Wiring Reference Balanced Co...

Page 15: ...ller soft ware manual for more information Possibility of direct connection point to point between a computer and a DMA 8X8 device 3 4 1 Connecting the DMA 8X8 to the Tecnare DSP controller Software Install the Tecnare DSP Controller software in your Computer and connect it on the same network of DMA 8X8 Launch the software and go to Device List menu fig 10 on the upper right corner and wait while...

Page 16: ...in the rear panel fig 11 used for serial communication Tx sending or data output Rx receiving or data input allows the communications with a third party control device RS485 can be used for voice tracking control or other output commands or for bus input control A central com mand can be used to conveniently integrate it into your software Baud Rate 115200 default Data bits 8 Parity None Stop bits...

Page 17: ...tput These outputs may be assigned by the logical output control module of the software Polarity and threshold can be definde as well Fig 12 RS 232 RS 485 control Ports 3 8 USB Soundcard USB Soundcard is used for recording and broadcasting audio using personal computers The cable used is Type B USB Fig 13 For initial connection Found New Hardware will pop up on computer screen and the driver will ...

Page 18: ...volume control source selec tion and other functions can be performed via UDP Fig 13 Application Example 5 Oled Screen The Control Panel must be connected to the system through Ethernet and supplied by PoE OLED Control Panel consists of a 1 3 OLED screen and one Encoder knob OLED screen display will show a classified according to a menu There is a total of three types of items including menu butto...

Page 19: ...otary knob on key panel The knob is used to adjust gain and 8 keys can be used to set different functions through programming These include volume adjustment mute preset and command Configuration will be carried out through the software Fig 15 Key Panel Panel A DMA8X8 6 1 Operations 1 Key indicator stays on which indicates the key is configured with mute function 2 Key indicator keeps flashing whi...

Page 20: ...rol Protocols RS 232 RS 485 and UDP transport layer DSP Processor ADI SHARC 21589 Sample Rate 48khz 24bits Work Mode Stereo Bridge Mono Free Matrix System Delay 3 ms POWER SUPPLIES Input voltage AC 230 v 50 60 Hz nominal 10 110v optional using TRF Max Power Consumption 40 W THERMAL One variable speed fan Airflow is from right to left PHYSICAL Height 1HU 44mm Width 482mm 19 front panel 440mm 17 32 ...

Page 21: ...otatory button Communication Ethenet Power Supply PoE not included Colour White Dimensions WxDxH 96 x 33 x 156 mm Shipping weight 550g REGULATORY COMPLIANCE This product complies with the EMC LVD directives as issued by the Commission of the European Community Compliance with these directives implies conformity with the following European standards EN55103 1 Electromagnetic Interference Emission E...

Page 22: ...22 Software Installation w w w t e c n a r e c o m DMA 8X8 DSP MATRIX rev 1 0 DMA 8X8 ...

Page 23: ...23 Software Installation w w w t e c n a r e c o m DMA 8X8 DSP MATRIX rev 1 0 DMA 8x8 ...

Page 24: ...ility for any errors or in accuracies that may appear in this manual Except as permitted by applicable copyright law no part of this publication may be reproduced stored in a retrieval system or transmitted in any form or by any means electronic mechanical recording or other wise without prior written permission from Exel Acoustics Tecnare and PCC Net are trademarks of Exel Acoustics SL System Eng...

Page 25: ...EXEL ACOUSTICS SL CL Encinar 282 Pol Ind Monte Boyal 45950 Casarrubios del Monte To Spain www tecnare com www facebook com tecnare T 34 918 170 110 34 918 171 001 rev 1 0 2022 ...