9
MENU CONFIGURATION:
The screen usually shows the production programmed on the upper line and the system status
on the lower line. There are two menus; the INFO information menu and the CONFIG
configuration menu.
LANGUAGE
screen: Pressing
CONFIG
shows the language selected at this time. The
language can be changed using the +/- buttons and searching for another: (English, Spanish,
Catalonian, French, Flanders, Italian and Russian*). Whether the language is changed or
not, pressing
CONFIG
passes to the next screen and pressing
ENTER
returns to the start
screen.
ORP
screen: Shows the current selection. The +/- buttons are used to change the current
option (- = No) (+=Yes). If “No” is selected, the
pH
screen will appear. If the option is
YES, by + / - we can choose how we want it to work: 4-20mA, 0-10V, NC contact, NO
contact, FIX or ORP
(for ORP see page 24)
. Once selected, by pressing
CONFIG
we
then pass to the next screen and by pressing
ENTER
we return to the home screen.
Screen
pH
: If we choose "NO" then the screen goes to the
CLEANING HOURS
. If the
option is YES we then open the
pH
menu
(see page 26).
CLEANING HOURS
screen: Shows the current selection, if the selection is changed by
pressing
CONFIG
, the
SEAWATER
screen will appear. Use the +/- buttons to change
the current option (no cleaning or every 3h, 4h up to 8h). The hours selected are those that
will change the polarity.
The higher the calcium content in the water, the less time will
pass between changes in polarity!
Once the time has been selected by pressing
CONFIG
,
the next screen will appear and pressing
ENTER
will return to the start screen.
SEA WATER
screen: Shows the current selection. If the selection is not changed, pressing
CONFIG
will go to the
ELECTRODE HOURS USE
screen. Use the +/- buttons to change
the current option (Yes / No). Press
ENTER
to return to the start screen.
ELECTRODE HOURS USE
screen: shows the total and partial hours of operation: Pressing
CONFIG
goes to the next screen
SET TO ZERO
and pressing
ENTER
returns to the start
screen.
SET TO ZERO
screen: Use the + / - buttons to set the partial hours counter to zero. The total will
not change. When the
CHECK CELL
LED is illuminated, requesting to check the electrode ,
and once it has been checked, go to this screen and set the partial to zero, which will turn off the
LED. If do not set to zero (No -) is selected, the system will return to the start menu. If yes
(Yes +) is selected, the set to zero screen will be displayed and the system will return to the
start screen.
H HOW TO MOVE AROUND THE MENUS: