MAINTENANCE:
When the unit has been operating for 500 hours, the CHECK CELL alarm will activate. This
is a reminder to carry out an inspection operation and maintenance, if necessary, in case
calcium deposits are observed on the electrodes (page 20).
To reset the counter to zero, go to the
HOURS OF USE
screen in
CONFIG
and this will
enable the unit to advise within another 500 hours.
•
RE-POSITION:
When the electrode is inactive (depleted), the unit activates the alarm. The saline
electrolysis is made up of titanium laminates covered in high-noble metal oxides. This covering
also has a limited lifetime.
After several thousand hours of service, the covering will desactivate and must be replaced.
In order to confirm the depletion, the output current must be compared in the two polarities. If
depletion exists, differences above 30% must be observed. When this occurs, the unit will
also show the
LOW SALT
alarm.