50
4.
Empty the dosing pumps of both the supplied dosing system (H
2
O
2
and ECOFLOC);
5.
Empty and clean well the tanks both the supplied dosing system (H
2
O
2
and ECOFLOC);
6.
Close all the insolation valves installed for each loose supplied parts, if any;
7.
Empty the sump of the safe filter (refer to the
MAINTENACE INSTRUCTIONS
section) of the U.V. Sterilizing system,
remove and the bag cartridge and re-install the sump;
8.
Empty the radiation chamber and uninstall all the related U.V. lamps and quartz sleeves (refer to the
MAINTENACE
INSTRUCTIONS
section) and store them in a safe place at a temperature from 0°C to 50°C;
DANGER:
Quartz tubes are fragile and may cause serious injury when broken. Consequently they must be
handled with care, protecting the hands by wearing gloves that guarantee adequate protection.
9.
Empty each of the tank of the Multimedia Filter Station (refer to the
MAINTENACE INSTRUCTIONS
section);
10.
Close all the pump inlet valves, i.e. valve between collecting tank and filling pump, valve between sea water inlet and sea
water pump. And be sure pipes and valves are completely empty;
11.
If the temperature exceeds -30÷60 °C range, remove the Main Control Box (item
B
on the picture below) from the Main
Unit, disconnecting all cables through the cable glands and store it in a safe place at a temperature from -30°C to 60°C.
12.
If the temperature exceeds -20÷200 °C range, disconnect all the level sensors (item
D
on the picture below) installed on
the treatment tank and store in a safe place at a temperature from -20÷200 °C.
13.
If the temperature exceed -40÷80 °C range, uninstall the motorized actuator (item
E
on the picture below) of the Discharge
Valve (V1), and store it in a safe place at a temperature from -40°C to 80°C.
14.
If the temperature exceed 1÷80 °C range, uninstall the pressure switch (item
C
on the picture below) installed on the
treatment tank (only for the plants with the tank in PP), and store it in a safe place at a temperature from 1°C to 80°C.
15.
Fig. 15.1-1 – ECOmar S main unit
16.
If the temperature exceeds 5÷40 °C range, uninstall both the supplied dosing system (H
2
O
2
and ECOFLOC) and store
them in a safe place at a temperature from 5°C to 40°C.
17.
The storage temperature of the H
2
O
2
solution must be that indicated in the relative safety data sheet and it may never be
exposed to direct sunlight or to high humidity conditions. If any abnormal condition, indicated in the safety data sheet,
occurs the solution is no longer effective, therefore replace the chemical solution (refer to the item safety data sheet).
18.
The storage conditions and temperature of the supplied ECOFLOC must be those indicated in the related safety data sheet.
If any abnormal condition, indicated in the safety data sheet, occurs the ECOFLOC is no longer effective, therefore
replace the chemical mixture (refer to the item safety data sheet).
19.
If the temperature exceed -40÷80 °C uninstall the motorized actuator of the Sludge Discharge Valve (V2), and store it in
a safe place at a temperature from -40°C to 80°C;
20.
If the temperature exceed 5÷45°C uninstall the Multimedia Filter Station, and store in a safe place at a temperature from
5°C to 45°C.
21.
The storage conditions of the fine and coarse Quartzite must be those indicated in the related safety data sheet. If any
abnormal condition, indicated in the safety data sheet, occurs the media is no longer effective, therefore replace the media
(refer to the item safety data sheet).
D
B
E
A
C