TECNO AIR SYSTEM
Essege Group
pag. 36 di 40
7.STOVE CLEANING AND STORAGE
Keep clean from dust all surfaces of the stove and using a damp cloth .
To clean the glass using a damp cloth or specific products for glass.
Keep clean all the internal parts of the stove .
Clean periodically the fan air intake located on the back of the stove and it using a vacuum cleaner.
It is advisable to periodically clean the tank during the season of use the stove (if you do not use the stove for
a long time or during the summer keep empty the tank ) leaving completely burn the fuel , wait for the stove
become cool and remove the tank by taking out from the attached to the stove. Clean off any combustion
residues with a damp cloth (use of a hand protection gloves for maintenance work ) , put it back into the
place. All maintenance operations must be performed with the stove off and well cooled .keep the stove
clean and dry .
Keep pets and minors away from the combustible.
8.GUIDE TO SOLVE SMALL PROBLEMS
The stove do not start in stand by mode:
Check for electrical voltage and correct plug insertion, check the electrical outlet fuse. If the problem persists
contact qualified service technician.
Smoke comes out:
Unsuitable fuel, or presence of flammable material outside the tank or inside the stove.
The burner darkens:
It is normal for the brazier to blacken is due to the heat and the flame that goes to squeeze the steel. Wait for
the stove to cool down, clean any traces of residual soot on the burner with a cloth
wet.
The stove comes off:
Check the bioethanol level.
The stove do not start:
Check the bioethanol level
On display appear H5:
Black out : shutdown lack of electricity (see alarm list table)
On display appear H6:
Thermocouple faulty or disconnected (see alarm list table)
On display appear H7:
Temperature anomaly (switch off for excessive temperature ) (see alarm list table)
The remote control doesn’t work:
Check battery level
In case of damage and/or malfunction of the appliance, please refer to qualified service center only.
9.GUARANTEE
Warranty period is 24 months from date of purchase and extended to all parties. It expires if the stove is
improperly used or tampered by unauthorized personnel.
All defects in materials and workmanship are repaired free of charge (parts and labor) with the only charge
of the exitfee.
Expressly reject any claim or demand compensation.
This warranty is not valid if repairs or replacements are not performed by authorized personnel or if not-
original parts are fitted on.