IST-2293.PM02.01/B
Istruzione / User’s Manual / Manuel d’utilisation
Pag.1/10
(IST-2293.PM02.01-B_TS293PM.doc - 15.04.2011)
Trasmettitore di Gas infiammabili con uscita 4÷20mA
Flammable Gas Detector with 4÷20mA output
Sonde a transmetteur 4÷20mA pour gaz inflammables
TECNOCONTROL S.r.l. - Via Miglioli, 47 20090 SEGRATE (MI)
Tel. 02/26922890 - Fax 02/2133734
http:
www.tecnocontrol.it
e-mail:
info@tecnocontrol.it
TS293PM
Leggere Attentamente e Conservare quest’Istruzione.
Please read and keep this manual
Lire avec soin et garder la notice d’istruction
Marcatura ATEX /
Ex marking / Marquage ATEX
II 2G Ex d IIC T6 Gb
Numero di Certificazione /
Certificate number / numéro du certificat
CESI 03 ATEX 323 X
Modello / Model / Modele Calibrato per / Calibrated for / Tarée pour
Cartuccia/Cartridge/Cartouche
TS293PM
Metano
/ Methane / Méthane
ZSP05/EX
TS293PG
GPL / LPG / GPL
ZSP05/EX
TS293P
I
Idrogeno / Hydrogen / Hydrogène
ZSP05/EX
TS293PB
Benzina / Petrol / Essence
ZSP05/EX
TS293PX
Vedi Tabella 3 / seeTable 3 / Tableau 3
ZSP05/EX
Con Cartuccia Sensore Sostituibile
Inside Replaceable Cartridge Sensor / Avec Cartouche Capteur échangeable
Caratteristiche tecniche /
Technical specifications
/
Caractéristiques techniques
Alimentazione /
Power supply / Alimentation
12÷24Vcc (-10/+15%) 2W
12÷24Vdc(-10/+15%) 2W / 12÷24Vcc(-10/+15%) 2W
Sensore /
Sensor Type / Capteur
Catalitico
Pellistor /
Catalytic
Pellistor /
Catalytique
Pellistor
Cartuccia Sensore /
Cartridge Sensor / Cartouche capteur
Sostituibile
/
Replaceable / échangeable
Uscite /
Outputs / Sortie
4 ÷ 20 mA lineare
/ Linear / linéaire
Resistenza di carico
/ load resistor / résistance de charge
50 ohm / 12Vdc (
-10%
) - 500 ohm / 24Vdc (
-10%
)
Campo di misura /
Standard Range / Champ de mesure
0 ÷ 100 % LIE /
LEL
Limite Scala / Limits
/
Limite échelle
100 % LIE /
LEL
Vita media in aria pulita /
Average Life in fresh air / Vie moyenne en air pur
5
anni
/ years / ans
Tempo di risposta /
Response Time
/
Temps de réponse
T
90
< 60 secondi /
seconds / secondes
Ripetibilità /
Repeatability / Répétitivité
5% del segnale /
signal
Precisione
/ Accuracy / Précision
± 2% LIE /
LEL
Linearità
/ Linearity / Linéairite
Fino al /
up to /
jusqu'à
60% LIE /
LEL
Deriva a lungo termine in aria pulita
Long time drift
in fresh air
/
Dérive à long terme en air pur
< ± 5 % LIE anno /
LEL year / LIE/an
Tempo massimo di immagazzinamento
Max Storage Time / Temps maximum de stockage
12 mesi / 12 month
/ 12 mois
Temp./umidità di immagazzinamento
/
Storage Temp-Humidity
Température et hygrométrie de stockage
-20 ÷ + 55°C / 5 ÷ 95 % RH
non condensata /
non condensed / non condensée
Temp./umidità di funzionamento
/
O
peration Temp./Humidity
Température et hygrométrie de fonctionnement
-10 ÷ + 50 °C / 10÷90 % RH
non condensata /
non condensed / non condensée
Pressione /
Operation Pressure
/
Pression
de fonctionnement
Atmosferica
/
Atmospheric/ Atmosphérique
±10%
Dimensioni - Peso
/ Size- Weight / Dimensions du boîtier - poids
190 x 105 x 83 mm / 1 Kg
I
DESCRIZIONE ............................................................................................................................ 2
NOTE SUI VARI MODELLI..................................................................................................................... 2
FUNZIONAMENTO ................................................................................................................................. 2
INSTALLAZIONE.................................................................................................................................... 2
AVVERTENZE ........................................................................................................................................ 3
VERIFICHE E CALIBRAZIONE .............................................................................................................. 3
GB
DESCRIPTION ............................................................................................................................ 4
NOTES ON THE AVAILABLE MODELS ................................................................................................ 4
OPERATIONAL DESCRIPTION ............................................................................................................. 4
INSTALLATION ...................................................................................................................................... 5
WARNING............................................................................................................................................... 5
TEST and CALIBRATION ...................................................................................................................... 5
F
DESCRIPTION ............................................................................................................................ 6
MODÈLES............................................................................................................................................... 6
FONCTIONNEMENT .............................................................................................................................. 7
INSTALLATION ...................................................................................................................................... 7
INSTRUCTIONS ..................................................................................................................................... 8
VÉRIFICATIONS ET ETALONNAGE ..................................................................................................... 8