TECHNICAL INFORMATION 

ASSEMBLY, USE AND MAINTENANCE INSTRUCTIONS 

 

 

HEATING UNITS 

WITH ATMOSPHERIC BURNER 

 
 

SERIE SR-UT SR-UT/K 

 

 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 

Manual attached to the USE AND MAINTENANCE INSTRUCTIONS of the UT and UT/K series 

 

 

As to what is not expressly mentioned in this manual, it is valid what is set forth in the manual ASSEMBLY USE AND 

MAINTENANCE INSTRUCTIONS of the UT and UT/K series appliances

 

 

 

Summary of Contents for SR-UT 106

Page 1: ...HERIC BURNER SERIE SR UT SR UT K Manual attached to the USE AND MAINTENANCE INSTRUCTIONS of the UT and UT K series As to what is not expressly mentioned in this manual it is valid what is set forth in...

Page 2: ...d TRADE NAME TYPE TRADE NAME TYPE SR UT 26 1 SR UT K 26 7 SR UT 36 2 SR UT K 36 8 SR UT 46 3 SR UT K 46 9 SR UT 66 4 SR UT K 66 10 SR UT 86 5 SR UT K 86 11 SR UT 106 6 SR UT K 106 12 5 0 WARRANTY The...

Page 3: ...is heated increasing its temperature then it can be distributed both directly and through proper channels Trough this heating system the plant costs can be remarkably reduced and a reliable operating...

Page 4: ...outdoor installation design TYPE 1 7 2 8 3 9 4 10 A mm 460 460 460 460 B mm 460 460 460 460 C mm 840 840 840 D mm 464 464 464 464 E mm 435 515 695 940 F mm 464 464 464 464 G mm 350 460 655 900 H mm 27...

Page 5: ...GHT Type 5 6 11 12 This drawing represents the outdoor installation design TYPE 5 11 6 12 A mm 460 460 B mm 460 460 C mm 895 895 D mm 464 464 E mm 1300 1540 F mm 464 464 G mm 1260 1500 H mm 27 27 TYPE...

Page 6: ...s in force generally special authorisations are to be obtained e g town planning architectural fire fighting environmental regulations etc Therefore before installing the appliance it is advisable to...

Page 7: ...s follow the instructions included in the relevant package 37 0 CONDENSATION CHECK The appliance is designed to be operated with the heating capacity and the air flow rate specified in the Data Sheet...

Page 8: ...should they be accidentally torn off it will be the last to be detached Have authorized personnel check that the wire sections and the electric plant are adequate for the max absorbed power specified...

Page 9: ...flow generated by the fan is essential Therefore avoid any obstacles hindering air supply and return Check that there is no fuel leakage Check that the fuel flow is correct by reading the meter Check...

Page 10: ...ing wipe carefully the surface Do not use sponges with abrasive products or washing powder During the installation the transparent film protecting the pre painted metal sheet shall be removed 50 0 SMO...

Page 11: ...larly carry out a combustion analysis not least in compliance with the relevant regulations 57 0 HEAT EXCHANGER CLEANING The heat exchanger cleaning inside and outside is to be performed by skilled an...

Page 12: ...9 tel 0461 53 16 76 fax 0461 51 24 32 www tecnoclimaspa com tecnoclima tecnoclimaspa com Since our Company is constantly committed to improve its products their esthetical features size technical data...