background image

IST-2138.EO01.01

 

Istruzione / User’s Manual / Manuel d’utilisation 

Pag.11/11

 

 

 

 

TECNOCONTROL S.r.l. Via Miglioli 47 SEGRATE ( MI ) 

 Tel: 02/26 92 28 90   Fax: 02/21 33 734

 

 

 

 

 

190 

65 

83 

105 

70 

Ø42 

107 

Fig. 1 –

 

Dimensioni /

 Size / Dimensions 

Imbocco Femmina ¾” Gas Conico UNI 6125 

”¾” UNI 6125 Female Gas Conical Thread 

Entrée femelle ¾” Gaz Conique UNI 6125

 

 

 

12

-2

4V

 

m

A

 

1

 

2

 

3

 

4

 

ON

 

OFF

 

SET

 

Dip Switch

 

 

TP1   TP2

 

Fig. 2 -

 

Schema di collegamento 

/ Wiring diagram / Schéma

 

A

L

2

 

A

L

3

 

A

L

1

 

F

A

U

L

T

 

1

 2

 3

 

5

 

4

 

6

 7

 8

 

F1 

F2 

Scheda Uscite Relé 

Relays Output Board 

Sortie sur Realis

 

12÷24Vdc 

Alimentazione 

Power Supply 

Alimentation

 

Centrale rivelazione gas 

Gas Central Unit

 

Centrale de détection

 

RL

 

-

 

+

 

Uscita in 4÷20 mA 

4÷20 mA Output 

Sortie en 4÷20 mA

 

Test Uscita  

Output Test 

Sortie Test 

40÷200mV

 

mV

 

 

 

 

0,3 L/min

 

Fig. 3 -

 Tester di calibrazione 

/ Calibration Tester / Kit de Calibration 

 

 

Alimentazione 

/ Power Supply / Alimentation

 

100

 

300

 

400

 

500

 

50

 

0

 

5

 

200

 

Vdc

 

RL=Resistenza di carico 

/ Load resistor / Resistance de charge

 

RL

 

Ohm

 

Fig.4 -

 

Alimentazione / Resistenza di Carico 4÷20mA 

Power supply / Load resistance diagram 4÷20mA 
Alimentation / Résistance de charge 4÷20mA

 

600

 

0

 

10

 

15

 

20

 

25

 

28

 

650

 

10,8

 

24

 

Area di funzionamento 

Allowable oparating region 

350

 

700

 

800 

 

 

Summary of Contents for SE138EO

Page 1: ... linéaire Campo di misura Standard Range Champ de mesure 0 25 0 O2 Limite del Sensore Sensor limits Limite échelle 30 O2 Vita media in aria pulita Average Life in fresh air Vie moyenne en air pur 2 anni years ans Tempo massimo di immagazzinamento Max Storage Time Temps maximum de stockage 3 mesi 3 month 3 mois Tempo di risposta Response Time Temps de réponse T90 30 secondi seconds secondes Ripetib...

Page 2: ... di stabilizzazione del sensore segnalata dal lampeggio del Led giallo FAULT Dopo circa 60 secondi il Led giallo si spegne e si accende il Led verde ON che indica il normale funzionamento Dopo questo tempo il sensore è in grado di rilevare il gas ma raggiunge le condizioni di stabilità ottimali dopo circa 15 minuti di funzionamento continuo Funzionamento Normale deve essere acceso il solo Led verd...

Page 3: ...eggiarsi anche se è esposto a concentrazioni di O2 molto elevate oltre il 30 In questi casi il sensore deve essere sostituito Attenzione i sensori elettrochimici per Ossigeno contengono una piccola quantità di acetato di potassio che è cor rosivo Normalmente non si verificano perdite dal sensore questo può essere causato solo da un azione meccanica violenta o un uso oltre i limiti di funzionamento...

Page 4: ...uccesso la Calibrazione in Aria è comunque possibile controllare la corretta risposta del rilevatore al gas uti lizzando la miscela di gas sopra indicata Infilare il TC011 sul portasensore regolare il riduttore della Bombola in modo che il flussometro indichi circa 0 3 l min vedi Fig 3 Attendere circa 1 2 minuti e controllare che il rilevatore vada in allarme come decritto nel capitolo Funzionamen...

Page 5: ...device If the condition does not change it will be necessary to replace the unit and or send it back to the supplier to repair Yellow and green Led activates FAULT relays activate and 0mA output signal this happens when the Cartridge Sensor is not working First try to perform the procedure of Calibration in Air as described in the section Test and Calibration Calibration in Air finally try to repl...

Page 6: ...Led relay ALARM2 with the 2 red Led relay ALARM3 with the 3 red Led At the end all the Led will remain lighted for around 5 seconds then the central returns at the conditions of normal operation It is advisable to perform this operation every 12 months according to the use Note this function is not working if the 1 and or the 2 and or the 3 red Led have already turned on CALIBRATION IN AIR Calibra...

Page 7: ...ment normal Led jaune FAULT capteur en panne ou déconnecté ou saturé ou échu Touches F1 et F2 pour les opérations de vérification et calibrage CARACTÉRISTIQUES DU GAZ Le SE138EO permet de détecter l Oxygène O2 qui est un gaz incolore inodore légèrement plus lourd que l air sa densité relative à l air est de 1 1 Ce n est pas un gaz inflammable mais étant fortement oxydant il réagit avec les matéria...

Page 8: ... plancher l oxygène ayant une densité proche de celle de l air Raccordements électriques Fig 2 la distance maximale à laquelle chaque détecteur peut être alimenté est indi quée dans le Tableau 1 en fonction de la section du câble utilisé Dans le cas d alimentation de plusieurs détecteurs en parallèle il est nécessaire de calculer la chute de tension sur les portions communes des câbles Un câble sa...

Page 9: ... à à la fin Durant la procédure une rare possibilité existe que la led jaune clignote chaque 8 secondes dans ce cas inter rompre la procédure puis exécutez le contrôle en coupant et en rétablissant l alimentation du détecteur En cas de persistance il sera nécessaire de remplacer et ou renvoyer le détecteur au fournisseur pour réparation Important Durant l opération de étalonnage l appareil portant...

Page 10: ...l alimentatore a 12Vcc The maximum distance to install each detector from the 12Vdc power Supply Distance max d installation d un détecteur sous 12Vcc La max distanza cui può essere installato ogni rivelatore dall alimentatore a 24Vcc The maximum distance to install each detector from the 24Vdc power Supply Distance maxi d installation d un détecteur sous 24Vcc 0 75 mm2 26 Ω km 100 m 300 m 1 mm2 2...

Page 11: ... Output Board Sortie sur Realis 12 24Vdc Alimentazione Power Supply Alimentation Centrale rivelazione gas Gas Central Unit Centrale de détection RL Uscita in 4 20 mA 4 20 mA Output Sortie en 4 20 mA Test Uscita Output Test Sortie Test 40 200mV mV 0 3 L min Fig 3 Tester di calibrazione Calibration Tester Kit de Calibration Alimentazione Power Supply Alimentation 100 300 400 500 50 0 5 200 Vdc RL Re...