1_30_______FEET POSITIONING AND ADJUSTMENTS
Place the display cabinet in a complete horizontal position,
if necessary turn the adjustable screw feet
on the legs of the unit to adjust to the desired level;
use a spirit level to make sure is flat.
The unit must be
in a complete flat position in order to work properly and to allow proper drainage of condensed/defrosting
water; the position will also help avoid noisy motor vibrations.
1_35_______INSTALLING THE UNIT INSIDE THE POINT OF SALE
It is advisable to install the refrigerated table inside an area with an air conditioning system. Please note that malfunctions may
arise in areas that are not provided with air conditioning, e.g. condensation formation… etc.
Please pay special attention to the following guidelines for correct operation of the refrigerated table:
Do not position the unit in an area directly exposed to sun light or to other heating sources,
such as high intensity
incandescent lighting systems, ovens or other radiant heating sources, e.g. heating radiators etc.
Do not position the unit nearby door openings producing air currents,
whether doors or windows or directly exposed
to air from fans, vents or fan coil unit air conditioner.
Do not block or obstruct the air inlets of the built-in refrigeration unit.
Do not place any objects on the unit, including boxes or any other type of objects; leave the entire perimeter of
the unit completely free
so that air can circulate properly.
Do not place the refrigerated table inside areas with high relative humidity levels
(it may cause formation of conden-
sation)
Do not position the refrigerated table inside a closed niche or very close to the wall,
as there is not enough air circu-
lation and may cause the refrigeration unit to not work properly.
Don not place the unit one above another.
Make sure there is enough air circulation in the area, even during closing hours. This will allow the refrigeration unit to
work properly.
1_45
_______
Refrigerated display cabinet FITTED WITH BUILT-IN REFRIGERATION UNIT
Air inlets of display cabinet fitted with built-in refrigeration units, which are located at the air intake grille on the back
side of the refrigerated table shall never be blocked or obstructed; this will ensure proper air circulation. Therefore,
avoid leaving products or other materials on the perimeter of the refrigerated table.
Please be advised that an increase in room temperature or inadequate quantity of air on the refrigeration unit’s con-
denser, will reduce the performance of the unit, possibly causing deterioration of exposed products and greater energy
consumption. If the refrigerated table that is fitted with built-in condenser is tilted, make sure to wait at least eight hours
before starting the unit; this time will allow the oil to flow into all of the unit’s components, lubricating all parts once
again; the unit can be started once this process is completed.
1_50______Refrigerated display cabinet WITHOUT REFRIGERATION UNIT
(adapting a REMOTE UNIT)
Electrical connections must be carried out scrupulously in accordance with current electrical standards; please be ad-
vised that electrical and refrigerator installations must be carried out exclusively by qualified staff.
For all refrigerated tables without refrigeration units (under remote version) make sure that the unit is positioned in an area that is
protected against atmospheric agents, avoiding using the area as storage for materials.
Depending on the features of the con-
denser remote unit model, make sure to comply with the wall distances and distances to keep from other obstacles
in
order to provide
adequate air circulation
that can ensure the proper operation of the refrigerated table and making it easy for
maintenance.