MINI Cold-Room predisposed for remote unit.
Both of them include water pipe drain with siphon predisposed for water drain connection ( to be
install by the
customer)
You never install the MINI Cold-Room without siphon and to connect more drains of the same MINI
Cold-Room together. Each drain must have only one siphon.
For more information please, see the APPENDIX 3 “VERSION”.
1.5 INSTALLATION INSIDE YOUR SHOP/RESTAURANT / WORKROOM
It is advisable to install the
MINI Cold-Room
inside an area with an air conditioning system. Please
note that malfunctions may arise in areas that are not provided with air conditioning, e.g. conden-
sation formation
ATTENTION
In order to allow a good functioning of the
MINI Cold-Room
please draw attentions to the fol-
lowing instructions:
•
Do not place the MINI Cold-Room to a direct exposure of sunlight and to all the other
means of irradiation,
such as high intensity incandescent lights, cooking ovens, heating radiators.
•
Avoid to close the air in-take
of the monoblock or built-in unit.
• Do not put any material as carton or others, on the top of the MINI Cold-Room
in
which is positioning the monoblock unit or the condensing unit.
•
Do not positioning the MINI Cold-Room inside the area in which there is to much hu-
midity
(possible making condensation of the surface of the MINI Cold-Room).
• Do not positioning the MINI Cold-Room inside a close cavity
(there is no circulation of
air and the MINI Cold-Room will not run properly).
•
Do not positioning two or more MINI Cold-Rooms back-to-back position
(the unit will not be properly).
Verify that in the installation room there is enough air turnover, even during closing and rest hours.
In this way the expansion/condensing unit will work correctly.
1.6 WALL MINIMUM DISTANCE
In order to allow a good performance of the MINI Cold-Room, during the installation you must
respect the MINIMUM WALL distances :
not less than 5 cm all around the Cold-Room and not less than 40 cm from the momoblock, posi-
tionated on the top af the Cold-Room, to the ceiling of the room where the Cold-Room is placed.
1.7 MINI COLD-ROOM WITH BUIlT- IN UNIT
If the MINI Cold-Room is fi tted with built-in condensing unit, check if the foot board obstructs air circulation.
Do not put any cartoons or any others materials and do not close the air in-take and out-take on
all sides of the MINI Cold-Rooms.
For a good running and performance of the MINI Cold-Room, do not obstruct the condensing unit ventilation.