32
EN
All the air suction grids and air delivery grids must be always opening.
Check if the room is suffi ciently aired, even when the shop is closed. Avoid to obstruct the sources of air placing
objects along the perimeter of the MINI Cold-Room. It is necessary to place MINI Cold-Rooms at least fi ve
centimetres from the wall. Before activating electric connection clean the MINI Cold-Room completely by using
tepid water and neutral detergents (non-aggressive) . Dry it with a smooth rag.
1.8 MINI COLD-ROOM WITH REMOTE CONDENSING UNIT VERSION
The electrical and cooling connection must be done only from a qualifi ed technician.
We recommend to follow the electrical norms.
The engine of the MINI Cold-Rooms with remote refrigerating unit must be protected from atmo-
spheric agents and the room must not be used for storing goods (free space all around the remote
unit). Respect the spaces between the unit and the walls or others obstacles, in order to have a
good air exchange to avoid a good performance and easy maintenance during the cleaning of the
condensing unit. It is necessary to remember that higher room temperature and insuffi cient air cir-
culation around the condensing unit imply higher energy costs and worse technical performances
of the refrigerator, with a possible waste of the exposed goods.
2. ELECTRICAL CONNECTION AND EARTHING
2.1 ELECTRICAL POWER SUPPLY
The installation and the electrical connections must be carried out in conformity with the electri-
cal rules in force. These operations must be carried out by quali
fi
ed staff. The company declines
any responsibilities originated from the no observance of the above rules in force.
See the appliance electric diagrams at appendix – 6 at the end of this manual.
Before plugging in the MINI Cold-Room, it is necessary to proceed with its complete and
careful cleaning, using warm water with no aggressive detergents and drying with a soft
cloth all the humid parts (read with attention the chapter 3. cleaning).
In order to carry out a correct plug in you must proceed as follow:
1. Before the connection to the electrical supply it is necessary to verify that the frequency / tension of
the line correspond to those written on the identifi cation label of the MINI Cold-Room (APPENDIX
2 - IDENTIFICATION LABLE OF THE MINI Cold-Room). A var/- 10% of the nominal rated
voltage is permitted. It is needful to connect the appliance to an effi cient ground socket (see point 6)
2. It is advisable to install an onnipolar sectioning switch with opening of contacts at least 3 mm
wide at the source as for example automatic switch, fuse wire (the fuse screw must be removed
from the socket) switch for fault current and electricity meter.
3. In order to save the appliance from overload or short circuit, the connection to the electricity
has to be done through a magneto-thermal switch high sensibility (30 mA) with manual re-
establishment, of the right power.
4. For protective device size, consider the power consumptions showed on the identifi cation label
of the appliance (APPENDIX 2 – identifi cation label product)
5. It is necessary that the connection cable section is commensurate to the power consumption of the unit.
6.
The law requires that the unit is earthed; therefore it is necessary to connect it to an
effi cient earth connection. In order to prevent any risks if the electrical cable and the
compressor supplied are damaged, these must be replaced by qualifi ed technician.
Installation must be carried out only by qualifi ed technicians according to the regulation in
force. No liability whatsoever can be accepted if the above instructions in not complied with.