1.7 VERTICAL MULTI-DECK DISPLAY WITH BUILlT- IN UNIT
If the Vertical Multi-deck Display is
fi
tted with built-in condensing unit, keep it clear all around in
line to not obstructs air circulation
. Do not put any cartoons or any others materials that could obstruct
the air ventilation on all sides of the Vertical Multi-deck Display.
For a good running and performance of the Vertical Multi-deck Display, do not obstruct the condensing unit ventilation.
Air suction grid and air delivery grid positioned on the front and back sides of the Vertical Multi-deck Display
must be always opening.
Check if the room is suf
fi
ciently ventilated, even when the shop is closed. Avoid to obstruct the sources of
air placing objects along the perimeter of the Vertical Multi-deck Display.
It is necessary to place Vertical
Multi-deck Display at least
fi
ve centimetres from the walls
. Avoid placing products or other materials
on the perimeter of the refrigerator. Before activating electric connection clean the Vertical Multi-deck Display
completely by using tepid water and neutral detergents (non-aggressive) .
Dry it with a smooth rag.
1.8 VERTICAL MULTI-DECK DISPLAY WITH REMOTE CONDENSING UNIT VERSION
The electrical and cooling connection must be done only from a quali
fi
ed technician
. We recom-
mend to follow actual electrical standards and regulations.
The engine of Vertical Multi-deck Displays with remote refrigerating unit must be protected from
atmospheric agents
and the room must not be used for storing goods.
Leave free space all around the remote unit.
Respect the spaces between the unit and the walls or others
obstacles, in order to have a good air ventilation to avoid a good performance and easy maintenance during
the cleaning of the condensing unit. It is necessary to remember that higher room temperature and insuf
fi
cient
air circulation around the condensing unit imply higher energy costs and worse technical performances of the
refrigerator, with a possible waste of the exposed goods.
2 2. ELECTRICAL CONNECTION AND EARTHING
2.1 ELECTRICAL POWER SUPPLY
The installation and the electrical connections must be carried out in conformity
with the electrical rules in force. These operations must be carried out by quali
fi
ed
staff.
The Company
declines any responsibilities originated from the no observance of
the above rules in force.
See the equipment electric diagrams at the end of this manual.
Before plugging in the equipment, it is necessary to proceed with its complete and careful clea-
ning, using warm water with no aggressive detergents and drying with a soft cloth all the humid
parts (read with attention the chapter "CLEANING").
In order to carry out a correct plug in you must proceed as follow:
1.
Before the connection to the electrical supply it is necessary to
verify that the frequency / tension of
the line correspond to those written on the identi
fi
cation label
of the Vertical Multi-deck Display
(APPENDIX - Product identi
fi
cation plate). A var/- 10% of the nominal rated voltage is permitted.
It is needful to connect the equipment to an ef
fi
cient ground socket
2.
It is advisable to install an
bipolar sectioning switch with opening of contacts at least 3 mm wide
at the source as for example automatic switch, fuse wire (the fuse screw must be removed from the so-
cket) switch for fault current and electricity meter.