VULCANO
| User and Maintenance Manual | EN
29
3.
In order to save the equipment from overload or short circuit,
the connection to the electricity has to be done
through a magneto-thermal switch high sensibility
(30 mA) with manual re-establishment, of the right power.
4.
For protective device size,
consider the power consumptions showed on the identi
fi
cation label
of the equipment (APPENDIX - identi
fi
cation label product)
5.
It is necessary that the connection cable section is commensurate to the power consumption of the unit.
6.
The law requires that the unit is earthed
; therefore it is necessary to connect it to an ef
fi
cient earth connection.
7.
If the power supply cable is damaged, it must be substituted by the manufacturer or by its technical
assistance service or however by a person with similar quali
fi
cations
, so as to avoid all risks. No liability
whatsoever can be accepted if the above instructions in not complied with.
8.
In order to prevent any risks if the
the compressor supplied is damaged, these must be replaced
by quali
fi
ed technician
.Installation must be carried out only by quali
fi
ed technicians according to the
regulation in force. No liability whatsoever can be accepted if the above instructions in not complied with.
WARNING
Any operation of ordinary and extraordinary maintenance of the equipment must be done disconnec-
ting the electric power supply. This maintenance must be done by quali
fi
ed technician.
The plug has to be always connected to a
fi
xed outlet. It is strictly forbidden to connect the equipment
plug to an extension cord or an adapter.
2.2 START UP AND USE
WARNING
Before to proceed to the switch-ON of the equipment you have to verify as follow:
•
the equipment
fi
tted with built-in condenser must be transported solely in vertical position
,
if it is tilted, make sure to wait at least 8 hours before starting the unit; this time will allow the oil on the
compressor to
fl
ow into all of its components, lubricating all parts once again.
•
In order to adjust operating parameters consult the information on the electrical control
board section
in the user instructions enclosed herein.
• for equipment with built-in units make sure that the disconnecting switch is open, in position 0, OFF, before
connecting the plug into the power socket, then connect the plug and close the switch.
•
avoid setting temperatures lower than the table unit’s relative temperature.
•
the
fi
rst start-up operation for equipments or for remote units must be performed by quali
fi
ed staff.
Once the power line is connected to the refrigerated display cabient (see previous paragraph), power the unit by closing the switch.
After having checked as above, it is possible to start the equipment, giving electricity from the general power
pack. Press green button in position 1, ON.
WARNING
Before loading the food on the equipments, wait that the temperature needed is the same on the
control panel. Avoid to set a lower temperature than that suggested according to the category the
equipment belong to in order to avoid evaporator block.
To regulate functioning parameters please follow the instruction attached to the present manual.