VULCANO
| User and Maintenance Manual | EN
33
this operation shall be carried out by a quali
fi
ed technician
, in some cases manual defrosting may be
required and the command located on the control panel can be used, or simply switch off the cooling system
for the time required to melt the ice on the pipe coils (depends on room conditions and on the quantity of ice).
For units intended for frozen or packaged food products it is recommended to perform a complete monthly
cleaning, including a defrosting cycle.
It is advisable to clean the external part of the table unit on a daily
basis, as well as the internal part of the door nearby the gaskets
.
5.8 GARBAGE DISPOSAL
Plastic, gaskets, sheet metal, polyurethane components, panel controls and electric material in general must be
saved and/or dumped in public dumps and/or garbage authorized centre.
Be sure not to disperse.
Save the refrigerating gas and oil in special tanks, do not dispose of them in the sewage system but dump them
in according to your local laws.
5.9 REQUESTING SPARE PARTS
Requesting spare parts please report:
• Model of the item
• Serial number of the item
• Quantity of the spare part
Eventually enclose a picture of the part you need.
General product information:
code VERjkz (identi
fi
cation of single particular code of the family HSD
- Horizontal serve-over displays)
"VER" TYPE OF PRODUCT
possible options
VER = Vertical Refrigerators
"j" size (horizontal length) of EUT
possible options
0060 = length 60 cm
0090 = length 90 cm
0096 = length 96 cm
0100 = length 100 cm
0120 = length 120 cm
0125 = length 125 cm
0136 = length 136 cm
0140 = length 140 cm
0150 = length 150 cm
0180 = length 180 cm
0182 = length 182 cm
0200 = length 200 cm
0240 = length 240 cm
0250 = length 250 cm
0262 = length 262 cm
0280 = length 280 cm
0300 = length 300 cm
0350 = length 350 cm
0375 = length 375 cm
0380 = length 380 cm
"k" additional con
fi
guration of EUT
possible options
S = without motor (compresser)
C = with motor (compresser)
N = without motor (compresser) and without other
electric components; appliance
provide only with internai light - expositor unit
"z" additional con
fi
guration of EUT
possible options
W = with electrical defrost (resistance)
X = with hot gas defrost (additionat by-pass valve)
Y = Stopping defrost (compresser turn off)