TECNOEKA Srl ______________________________________________________________ use and instruction manual
page 6 _________________________________________________________________________________________
3. Technical specifications
Dimensions of appliance (mm) LxDxH
460x512x462
Weight of appliance (Kg)
25
Maximum load per tray (kg)
0,75
Maximum load (kg)
3
Convection heating element (kW)
2,5
Grill heating element (kW)
/
Max absorted power (kW)
2,6
Power supply voltage (V~)
230V~ (50/60Hz)
Power cable diameter
3x1,5 mm
2
Type of cable
H07RN-F
Connecting electric cable
Tipo Y
Class
I
Degree of protection against humidity
IPX3
Water pressure (kPa)
100-200 (EKF 412 U – EKF 412 ALU)
The noise level of the appliance in operation is below 70 dB (A).
The "technical data" plate is positioned on the side panel of the appliance.
4. Instructions for the installer
The following instructions are aimed at the qualified installer, to ensure that he carries out the
installation, adjustment and maintenance operations as correctly as possible and according to
current legal regulations. Any operation must be performed with electrical power cut to the
appliance. Before using the appliance, carefully remove the special adhesive film protecting the
parts in stainless steel. Do not leave any glue residues on the surfaces. If necessary, remove
them at once, with an appropriate solvent.
Fitting the feet - The feet are inside the appliance and must be secured on the four threaded
holes on the base.
Positioning - Position the appliance perfectly horizontally on a table or similar support (the table
or support must be at least 85 cm above the floor). Position it at a distance of not less than 10
cm from the side and rear walls, to enable natural ventilating air to circulate freely around it.
The appliance is ventilated through specific openings on the metal walls of the outer housing ,
and ensures efficiency and long-life. For this reason it is strictly forbidden to obstruct these
ventilation openings, even partially or for short periods. Failure to observe this specific
prohibition releases the manufacturer of the appliance from all responsibility and immediately
voids any guarantee rights for the said appliance, because its constructive conformity has been
voluntarily compromised. Furthermore, the appliance is not suitable for embedding and for
grouped positioning with other identical appliances.
2 anti-rollover brackets with relative fastening screws are fitted. The brackets have to be fixed to
the appliance through the holes present on the back panel for this purpose. The bases of the
brackets must be fixed to the base plane supporting the equipment, using screws suitable to the
material of the plane itself.