6. Adapting cook-top to different types of gas
Mod. KCP96 V – KCP96 VS – KCP5 96 V – KCP5 96 VS
To adapt the hob to a type of gas that differs
from the one tested in the factory (see data plate
or supplementary plate), replace the nozzles of
the five burners Remove the pan carrier grilles
from the hob and withdraw the movable parts of
the burners from their seats:
-
Remove the pot support grids from the
cook-top and remove the mobile parts of
the burners from their position.
-
Unscrew the jets (Fig. 2) using the 7 mm.
Key and replace them with the new ones
(see table 1). Check the exact
correspondence of the diameter indicated
on the table with that printed on the jets.
After having replaced the jets, set up all the
parts again and stick the new data on the
technical data plate.
Fig. 2
N.B. The burners don’t need any air regulation.
Minimum level adjustment - Burner minimum levels are preset for methane gas (G20)
operation. If operating on liquid gas (G30/G31) proceed as follows: ignite the burner at
minimum position, and, using a screwdriver, fully tighten the by-pass adjustment screw at the
side of the shank of the relevant tap. Check if the flame remains stable and uniform – to help
you check, rapidly turn the tap knob from maximum to minimum position. When you have
finished adjusting the by-pass valve, seal it with red paint. Make sure you fit a plate with the
new installation data. After having set the by-pass screw, seal it with red varnish.
Gas pressure (mbar)
Type of gas
Normal
Max.
Min.
Table 1
G30
30 35 20
G31
37 45 25
G20
20 25 17
Main nozzles diameter
(1/100 mm)
By-pass screw nozzles
diameter
(1/100 mm)
Consumption calculated with gross
heat values
Nominal
thermal
capacity
(kW)
Reduced
thermal
capacity
(kW)
G30/G31
30/37mbar
G20
20mbar
G30/G31
30/37mbar
G20
20mbar
G30
30mbar
(g/h)
G31
37mbar
(g/h)
G20
20mbar
(l/h)
Triple crown
burner Nr. 1
3.5 1.8 95
135
74 Regul. 255 250 334
Fast burner
Nr. 3
3 0.95 85 115 50 Regul. 218 214 286
Semi-fast burner
Nr. 1
1.75 0.6 65
97
40 Regul. 127 125 167
Mod. KC 96 V – KC 96 VS – KC 96 M – KC 96 MS – KCR 96 V
To adapt the cook-top to a different type of gas from the one used to test the device in the
factory (see data plate or supplementary plate), replace the nozzles of the five burners and set
the primary air flow by means of the appropriate tools. To do so it will be necessary to
disassemble the cooker cook-top in order to easily access the burners, the nozzle holders and
the tools used to adjust the primary air. Proceed as follows: