MAy-2015
30
– DECRIPTION OF THE MACHINE –
4.3 - NOISE MEASUREMENTS
4.3.1 - VALUES
• In line with Directive 2000/14/EC "Noise emission in the environment"
• The noise emission values are reported from the work station (pos1) or the driving position (pos2).
• The emission values are measured 1.60 m off the ground and 1 m from the surface of the machine.
• The values are expressed in Decibels (Db)
Fig.3
pos 1
pos 2
Table of measurements
Vectis
type of equipment
PRECIJET (Vitivario boom)
PNEUMATIQUE (Vitisit boom)
noise meter position
pos1:
work station
(valve pack)
pos2:
driving position
(closed cab)
pos1:
work station
(valve pack)
pos2:
driving position
(closed cab)
ventilation
disenga-
ged
engaged disenga-
ged
engaged disenga-
ged
engaged disenga-
ged
engaged
acoustic pressure
Db (weighted A)
92
94
(b)
(b)
(a)
(a)
(b)
(b)
max. value
acoustic pressure
Db (weighted C)
94
94.5
(b)
(b)
(a)
(a)
(b)
(b)
Measurement conditions
coupled to the tractor
no
(a)
no
(a)
on bench
yes
(a)
yes
(a)
work station
yes
no
yes
no
driving position
no
yes
no
yes
appliance working
yes
yes
yes
yes
tank empty
no
(a)
no
(a)
tank full
yes
(a)
yes
(a)
on-site
no
(a)
no
(a)
on bench
yes
(a)
yes
(a)
(a): values to be defined, (b): the acoustic pressure level in the tractor cab, partly depends on the vehicle used.
4.3.2 - REFERENCE MEASUREMENT APPLIANCE
Summary of Contents for VECTIS 1000
Page 2: ......
Page 8: ...May 2015 8 MACHINE IDENTIFICATION ...
Page 40: ...May 2015 40 DECRIPTION OF THE MACHINE ...
Page 112: ...May 2015 112 MACHINE MAINTENANCE ...
Page 128: ...May 2015 128 ENVIRONMENTAL PROTECTION ...
Page 129: ...May 2015 129 Chapter 8 8 PERSONAL NOTES ...
Page 130: ...May 2015 130 PERSONAL NOTES ...