RECALLING A STORED PROGRAM
When the appliance is
ON
, press push-
button 9
briefly; display 16
will
show program P1. Use push-buttons 7
and 8
to select the required program.
Start up the cycle by pressing push-button 6
.
6.5
DISPLAYING THE THREE LATEST
HACCP ALARMS (PUSH-BUTTON 10)
Set the machine to
ON
.
Press and hold down push-button 10
for
more than five seconds (relative LED illumi-
nates) to enter the alarm display function
(date, hour and minute, alarm type and max-
imum temperature detected).
Every time the HACCP push-button is
pressed, the stored data are displayed.
EXAMPLE:
ALL.11
Display
15
Display
16
---
Str (start)
12
hr hour
29
min minutes
6
day days
8
mon month
03
yr year
End
end
13
Hr
21
min
6
day
8
mon
03
yr
24
maximum temperature
detected inside the cell
6.6
PRINTING OUT STORED DATA
PUSH-BUTTON (10)
With the appliance in
STAND-BY status,
press and hold down push-button 10
for
more than five seconds to print out the latest
work cycle.
(With the appliance in STAND-BY status,
press push-button 10
once to print out
HACCP data). When the appliance is operat-
ing and the printer is on, the current cycle will
be printed out.
6.7 FORCED VENTILATION FUNCTION
To activate this function when the appliance
is
ON
, press push-button 12
for more
than five seconds. The fan will continue to
operate even when the cell door is open.
During forced ventilation, display 16
will show
“AIR”.
6.8 MANUAL DEFROSTING
To activate this function when the appliance
is
ON press push-button
12
(relative
LED illuminates).
If conditions allow it (the temperature detect-
ed by the evaporator probe must be lower
than the set point in the program parame-
ters), the appliance will perform a defrost
cycle. Display 16
will show
“dEF”.
To immediately stop a defrost cycle, press
push-button 12
.
6.9
AUTOMATIC DEFROST CYCLES
(NOT AVAILABLE FOR E5-14)
The appliance automatically performs
defrost cycles during storage. Three defrost
cycles are performed during a 24-hour peri-
od(once every 8 hours).
The appliance automatically restarts once
the defrost cycle has been completed.
6.10 UV-C LAMP FUNCTION
Use this function to sterilize the interior of the
cell.
When the appliance is
ON
, press push-
button 11
(relative LED illuminates). The
UV-C lamp switches on and sterilizes the
interior for a default time of 30 minutes. To
interrupt the sterilization cycle, press push-
button 11
or open the cell door. When the
door is closed again, the lamp will remain off.