GB
53
Effect:
Any current chilling cycle is interrupted.
If a storage phase is in progress, the compressor and the fan set to stand-by sta-
tus.
When the appliance is in Stop status, press Start to set the compressor and fan
to stand by.
Beeper:
Activated (3 seconds, then a pause of 30 seconds) until the mute button is
pressed.
Display:
Alternates message “ALL 03” with standard display
Reset:
Automatically resets only when probe reading has returned to normal.
Optional probe alarm (ALL 04)
(disabled if no probe is connected)
Input SW2 (ALL 05) (door microswitch alarm)
Cause:
Input active for more than 5 minutes with appliance in start status.
Door open (close door) Microswitch fault (replace the microswitch)
Beeper:
Activated (3 seconds, then a pause of 30 seconds) until the mute button is
pressed.
Display:
Alternates message “ALL 05” with standard display
Reset:
Press the mute push-button (with beeper off).
Automatically resets if input value returns to normal Alternatively, switch off the
panel then turn it back on (stand-by).
Input SW1 alarm (ALL 06)
(Press. max for all models)
(Thermal-magnetic switch for E15-40 / E15-65 / E15.2/70 / T14/2 / E20 / T20 / T24 /
T30 / T40 / T50 models)
(Oil diff. pressure switch for E20 / T20 / T30 / T40 / T50 models)
Cause:
Input active for more than 5 seconds
Effect:
Sets the appliance to STOP.
Reset the max. pressure switch, thermal-magnetic switch or differential pressure
switch.
Beeper:
Activated (3 seconds, then a pause of 30 seconds) until the mute button is
pressed.
Display:
Alternates message “ALL 06” with standard display
Reset:
Press the mute push-button (with beeper off) with no alarm cause displayed